SAMES KREMLIN
Page 21
Manual : 573.176.112
PARAMETER 21 : CONFIGURATION PARAMETER OF THE RS 232 CONNECTION
RS232 7bits>00/8bits>10
300 >1 2400>4 SParit>20
600 >2 4800>5 Ppair>40
1200 >3 9600>6 P1pair>60
Can be programmed:
- The speed (300, 600, 1200, 2400, 4800, 9600 bauds) - respective code (1, 2, 3, 4, 5, 6), any other code
is considered for 9600 bauds
- The format (7 bits/ 8 bits) - respective code (00,10), any other code is considered for 8 bits
- The parity (without, with even parity, with uneven parity) - respective code (20,40,60), any other code is
considered for "without parity"
Serial connection not managed.
The parameter is taken into account only when switching on or reset of the bay.
PARAMETER 22 : CONFIGURATION PARAMETER OF THE RS 485 CONNECTION
RS485 8bits/sans Parite
300 ->1 2400->4
600 ->2 4800->5
1200->3 9600->6
The speed (300, 600, 1200, 2400, 4800, 9600 bauds) - respective code (1, 2, 3, 4, 5, 6) , any other code
considered for 9600 bauds, is the only parameter that can not be modified.
The format is fixed (8 bits) and the parity is not managed.
The parameter is taken into account only when switching on or reset of the unit.
PARAMETER 23 : RESPONSE ADDRESS OF THE ModBus SLAVE
Mini. limit
Maxi. limit
Value for the first operating
1
127
2
Any slave stays liable to the processing of the frames to the slave 0 however (refer to specification of protocol).
The parameter is taken into account only when switching on or reset of the unit.
PARAMETER 24 : PRESSURE SENSOR SCALE
Mini. Limit (bar)
Maxi. Limit (bar)
Value for the first operating (bar)
10
250
50
Nota : to take into account the modification of the parameter input "Reset"
PARAMETER 25 : POSITION SENSOR SCALE
Mini. Limit (mm)
Maxi. Limit (mm)
Value for the first operating
10
100
25
Nota : to take into account the modification of the parameter input "Reset"