Ex1:
Get the serial number
Command:
*IDN?
Return:
Instrument name, SN and factory name
10.2.2 System command
Command
Means
UPGRade
Software Upgrade
DISPlay:ENABle<Boolean> DISPlay:ENABle?
Set /Get the displays function state
10.2.3 Spectrum control command
1. Frequency
Command
Means
[SENSe:]FREQuency:CENTer<freq>
[SENSe:]FREQuency:CENTer?
Set /Get the center frequency
[SENSe:]FREQuency:STARt <freq>
[SENSe:]FREQuency:STARt?
Set /Get the start frequency
SENSe:]FREQuency:STOP <freq>
[SENSe:]FREQuency:STOP?
Set /Get the stop frequency
[SENSe:]FREQuency:CENTer:STEP <freq>
[SENSe:]FREQuency:CENTer:STEP?
Set /Get the frequency step
[SENSe:]FREQuency:CENTer:STEP:AUTO
<Boolean>
[SENSe:]FREQuency:CENTer:STEP:AUTO?
Set /Get the step auto state
[SENSe:]FREQuency:SPAN <freq>
[SENSe:]FREQuency:SPAN?
Set /Get span
[SENSe:]FREQuency:SPAN:FULL
Set span to full span
[SENSe:]FREQuency:SPAN:PREVious
Set span to previous span
Ex1:
Set the center frequency to 300.33 MHz
Command:
FREQ:CENT 300.33 MHz
Ex2:
Get the frequency step auto state
Command:
FREQuency:CENT:Step:AuTO?
Return:
ON