• Drain the foam pump prior to removal from the system and close the foam tank valve.
• Routine inspection and maintenance must be performed as outlined in this Operation & Service manual.
• Only use lubricants and cleaning solvents listed in this manual for maintenance and repairs. Observe correct material
handling procedures when working with lubricants and solvents.
•
Slowly loosen the water and foam pressure line fittings and allow the pressure to escape. Release water and foam pressure
within the system before servicing the foam and fire pump system.
•
The foam concentrate liquid and foam/water solution that is “flushed” from the foam system shall be directed to a ‘safe’
foam concentrate collection location. The final installer and/or end-user shall be responsible for flushing the system.
• Do not operate the foam pump at pressures exceeding the maximum listed operating pressure of 300 PSI [20.7 BAR].
• The safety relief valve is supplied with the foam system, do not readjust the pressure setting.
• Always disconnect the ground and positive battery cables from the battery terminals, electrical wires and control cables
from the foam system and all other FoamPro equipment before electric arc welding at any point on the apparatus. Failure
to do so will result in a power surge through the unit that might cause irreparable damage.
•
All foam and water system flushing shall be conducted while operating through the fire pump supplied flushing system.
Refer to the ‘Flushing’ section of this installation manual.