MAX100/200-OPERATION Rev200813
60
(Continued Table 2. Error/ Warnings Codes and Troubleshooting)
Accumax Display Controller Errors and Warnings
Code
Message
Description/Cause
Corrective Actions
W0467
SYS. NO FOAM SHUTDOWN
System was shut down due to lack off foam.
Reestablish foam supply. Turn Foam On to
resume operation.
W0470
SYS. CAPACITY LIMIT
System foam output at max.
Demand exceeds system capacity.
Decrease demand for foam by reducing water flow
on some lines or closing one of the lines. Foam
may be lean when this message is displayed.
W0471
SYS. NO FOAM DETECTED
System no foam flow detected.
Foam pump is running dry. No-foam
shutdown timer started. System will
shutdown after timer elapses and no foam is
delivered to the system.
Current foam supply is empty.
Connect new foam supply.
Run pump until foam starts flowing again.
Accumax Water Valve Errors and Warnings – Accumax Fusion Only
E0003
NO VALVE
Water valve was not paired yet.
Water Valve data cable disconnected.
Defective valve actuator.
Water Valve not powered.
Wiring issue.
Pair valve with controller.
Check data wiring and power to valve.
E0004
NETWORK CONFLICT
More than 1 valve with the same Network ID.
New valve was added to network with ID that
already existed.
Valve Controller ID was not assigned
(is set to 0).
For new installation: complete pairing process
for all controllers. Pair valve if it was replaced/
serviced.
E0205
VALVE PRES. SENS.
Pressure sensor signal outside of range.
Pressure sensor is unplugged or not installed
on this valve. Pressure sensor wiring issue.
Check if sensor is installed and plugged in.
Check pressure sensor.
Check pressure sensor wiring.
E0210
VALVE OVERCURRENT
Valve overcurrent while closing.
Mechanical obstruction or debris
inside valve.
Valve position must be calibrated.
Valve actuator requires lubrication.
Electric motor problem.
Check valve for any object that may prevent it
from closing.
Calibrate valve.
Lubricate Valve Actuator.
Check electric motor.
E0211
VALVE OVERCURRENT
Valve overcurrent while opening.
Mechanical obstruction or debris inside
of valve.
Valve position must be calibrated.
Valve actuator requires lubrication.
Electric motor problem.
Check valve for object that may prevent it
from opening.
Calibrate valve.
Lubricate actuator.
Check electric motor.
E0212
VALVE HIGH CURRENT
Valve draws high current.
Mechanical obstruction or debris inside
valve.
Valve actuator requires lubrication.
Electric motor problem.
Check valve for object that may prevent it
from opening.
Lubricate actuator.
Check electric motor.
E0213
VALVE POS. SENS. FAIL
Valve position sensor failed. Normal current.
Internal issue with actuator.
Contact manufacturer.
Replace actuator.
E0214
VALVE POS. SENS. FAIL
Valve position sensor failed. Motor stalled.
Internal issue with actuator. Electric motor is
unplugged or has issues.
Contact manufacturer.
Replace actuator.
Replace motor.
E0215
VALVE POS. SENS. FAIL
Valve position sensor failed. High current.
Valve jammed.
Internal issue with actuator.
Short in wiring.
Electric motor issue.
Inspect valve for foreign objects.
Contact manufacturer.
Replace actuator.
Replace motor
E0220
VALVE NO MOTION
Valve does not move. Normal current.
Insufficient current to drive valve.
Internal issue with actuator.
Mechanical damage to valve.
Check valve power and wiring.
Inspect valve for foreign objects.
Contact manufacturer.
Replace actuator.
Содержание FoamPro Accumax II Fury