MAX100/200-OPERATION Rev200813
16
d.
Foam tank refilling (Specify size: ___”/mm)
e. Foam concentrate discharge (Specify size: ___”/mm)
f. Foam concentrate recirculation
Refer to drawing on the installation of the FOAM-AUX plumbing diagrams. The setup and operation of the system
is noted under the SETUP section of this installation manual.
Foam Aux Display and Installation
OEM
SIZE:
_ _ _
G/L
FOAM TANK
OPEN FOAM
CONCENTRATE
DISCHARGE
#5
METERING VALVE
SIZES: 1 1/2" / 40mm (Standard)
2" / 50mm (Optional)
1 1/2"
1 1/2"
1 1/2"
THREE WAY DIVERTER VALVE
SIZES: 1 1/2" / 40mm (Standard)
2" / 50mm (Optional)
FOAM TANK REFILL
#4
FOAM TANK
VENT
SIZES: 1 1/2" / 40mm (Standard)
2" / 50mm (Optional)
FOAM FLOW METER
PRESSURE TRANSDUCER
FROM FOAM
CONCENTRATE
MAINIFOLD
FOAM AUX DISPLAY
DISPLAY
OPERATIONS
1
2
3
4
5
6
FT -TO- FP
FOAM INTAKE
FLUSH
FOAM TANK REFILL
FOAM CONL DISCHARGE
FOAM RECIRCULATE
On FireLion and Edwards foam pumps a pressure gauge shall be installed next to the intake valve. The final installer
shall install the following warning label next to the foam intake valve and connection:
• WARNING:
foam intake valve (from either “suction” or “pressurized” foam supply) shall be ball valve controlled to
allow a
maximum pressure of no more than 50 PSI (3 BAR)
or foam pump damage will result. The foam intake shall
NOT be used for “flushing” purposes.
Содержание FoamPro Accumax II Fury
Страница 107: ...MAX100 200 OPERATION Rev200813 107 NOTES ...
Страница 108: ...MAX100 200 OPERATION Rev200813 108 ...