MAX100/200-OPERATION Rev200813
34
Foam Tank Size
This setting defines the foam tank capacity. This number is used to calculate the amount of time until the tank is depleted
at the current consumption rate. The "Foam Time to Empty" value can be selected as one parameter to be displayed on the
operator's screen. Confirm the selected unit of measure (UOM) is the correct one. To change the UOM, see USER SETTINGS ,
UNITS SYSTEM menu.
NOTE:
This setting is only used when the TankVision Pro is installed along with the AccuMax system
.
1. Select SETUP on the menu screen by pressing the
INCREASE
or
DECREASE
button. Press the
SELECT
button to access this menu.
2. In SETUP, select the 'FOAM TANK SIZE' item using the
INCREASE
or
DECREASE
button. Press the
SELECT
button to enter the setting screen.
3. The display will show the current foam tank capacity selected. To change
the value, use the
SELECT
button to increase, and the
ON/OFF
button to
decrease the value. To increment/decrement capacity automatically, press
and hold the either button.
4. To save the new value, press the
INCREASE
or
DECREASE
button until
'SAVE AND RETURN' item is selected. Press the
SELECT
button to save
the new value, and return to the previous menu. Or, press the
ON/OFF
button
to cancel the change.
TankVision Gauge Address Number
The setting selects the TankVision unit that matches the foam type used by AccuMax foam system. The TankVision
unit types are identified by the address number (201-Foam A, 202-Foam B, 200-Other)
1. Select SETUP item in the main menu. Press the
SELECT
button to access this menu.
2. Select the 'TANK GAUGE ADDR.' item. Enter this submenu using the
SELECT
button.
3. The display will show Foam Tank Class options. To change the
selection, press
INCREASE
or
DECREASE
button.
4. Press the
SELECT
button to apply the change. To return to the previous
menu, press the
ON/OFF
button.
Water Flow Sensor Location
This setting indicates if the water sensor is installed before the foam concentrate
injection point (WATER), or after the injection point (SOLUTION). NOTE: Make sure this setting matches the discharge
configuration to ensure proper foam solution percentage.
1. Select the SETUP item in the main menu. Press the
SELECT
button to access this menu.
2. Select the 'WT. FL. SENS. LOC.' item. Enter this submenu using the
SELECT
button.
3. The display will show a list of options. To change the selection, press
INCREASE
or
DECREASE
button.
4. Press the
SELECT
button to apply the change. To return to the previous
menu, press the
ON/OFF
button.
Содержание FoamPro Accumax II Fury
Страница 107: ...MAX100 200 OPERATION Rev200813 107 NOTES ...