MAX100/200-OPERATION Rev200813
35
Reading Water Flow from Remote CAN Device (WT. FLOW SOURCE ID)
This setting selects the water flow reading source to be local, sensor connected to injector, or remote sensor connected
to another device on the CAN network. Use "LOCAL" option if the sensor is connected to the injector, or select the "DEVICE
ID" of the device providing the water flow reading.
1. Select SETUP item in the main menu. Press the
SELECT
button to access this menu.
2. Select 'WT. FLOW SOURCE ID.' item. Enter this submenu using the
SELECT
button.
3. The display will show a list of options. To change the selection, press
INCREASE
or
DECREASE
button.
4. Press the
SELECT
button to apply the change. To return to the previous
menu, press the
ON/OFF
button.
Hydraulic Controller Backup
The setting indicates if the Hydraulic Controller Backup option is installed.
1. Select SETUP item in the main menu. Press the
SELECT
button to access
this menu.
2. Select 'HYD CNTL BACKUP' item. Enter this submenu using the
SELECT
button.
3. Press
INCREASE
or
DECREASE
buttons to select the desired option.
4. Press the
SELECT
button to apply the change. To return to the previous menu, press the
ON/OFF
button.
Valve Polarity (for MAX200 Fusion models only)
Valve Polarity setting allows the valve direction of travel to be changed. If the valve opens when the
ON/OFF
button
is pressed, or closes when the
SELECT
button is pressed, then the valve polarity setting must be changed.
1. Select SETUP item in the main menu. Press the
SELECT
button to access this menu.
2. Select 'VALVE POLARITY' item. Enter this submenu using the
SELECT
button.
3. The polarity settings list will be displayed with the current setting selected. To change this setting, press
INCREASE
or
DECREASE
button to select the other setting. Press the
SELECT
button to apply the change.
To return to the previous menu, press the
ON/OFF
button.
NOTE
: After the polarity setting is changed, valve calibration is required. A message will be shown on the display
prompting the user to calibrate the valve. To immediately perform valve calibration, press
the
SELECT
button.
To perform calibration later, press the
ON/OFF
button.
The valve will not work correctly until the calibration
is done.
Flow Cut-off
The Flow Cut-off setting determines the lowest flow rate that will be displayed. Any flow rate below the set value
will be shown as 0.
1. Select SETUP item in the main menu. Press the
SELECT
button to access this menu.
2. Select 'FLOW CUT-OFF' item. Enter this submenu using the
SELECT
button.
3. The display will show the current Flow Cut-Off value selected. To change the preset value, use the
SELECT
button to increase, and the
ON/OFF
button to decrease the value.
4. To save the new Flow Cut-Off value, press
INCREASE
or
DECREASE
button until 'SAVE AND RETURN'
item is selected. Press the
SELECT
button to save the new value, and return to the previous menu. Or, press
the
ON/OFF
button to cancel the change.