MAX100/200-OPERATION Rev200813
28
Step
Device
Description
Menu Item
1
Set system unit of measure
All Display
Modules
Set preferred system unit of measure.
USER
SETTINGS /
UNIT SYSTEM
2
Set Display Module Unit ID
All Display
Modules
Set unique unit ID to each display module on the network.
Unit ID is used to identify and pair devices that work with specific
discharge/injection point of AccuMax system.
Redundant display modules should be set with the same Unit ID as
display module they should be redundant to.
SETUP/ UNIT ID
3
Setting Group ID
All Display
Modules
Set at factory as 0 - default.
Change ONLY if there are more than one AccuMax system on
the same CAN network. Group ID is used to group AccuMax
components into separate systems that will function independent
of each other.
SETUP /
GROUP ID
4
Pair Injector
All Display
Modules
In this process, specific Injector assembly is selected from list of all
available on network by its S/N. This Injector is assigned Unit ID
that matches Unit ID of Display Module used for pairing process.
Once complete, Display Module and Injector will have same Unit
ID and they will become a functional pair. Pairing for redundant
displays modules is not required.
SETUP / PAIR
INJECTOR
5
Pair Hydraulic Controller
Once using
any Display
Module
Hydraulic Controller are set to Group 0 at the factory.
In this process Group ID is assigned to Hydraulic Controller.
Change ONLY if there are more than one AccuMax system on
the same CAN network, or if hydraulic controller is set to wrong
Group ID.
SETUP / PAIR
HYDRAULIC
CONTROLLER
6
Pair Low-Flow
Once using
any Display
Module
Low-Flow Assembly is set to Group 0 at the factory.
In this process Group ID is assigned to Low-Flow.
Change ONLY if there are more than one AccuMax system on the
same CAN network, or if Low-Flow is set to wrong Group ID.
SETUP / PAIR
LOW-FLOW
7
Pair Valve (for MAX200
Fusion models only)
All Display
Modules
In this process specific Water Valve is selected from list of all
available on network by its’ S/N. This Valve is assigned Unit ID that
matches Unit ID of Display Module used for pairing process.
Once complete Display Module and Valve will have same Unit ID
and they become functional pair. Pairing for redundant displays
modules is not required.
SETUP / PAIR
VALVE
8
Water Flow Sensor Location
All Display
Modules
Set water flow sensor location that matches its installation
location: in water or in solution.
SETUP / FLOW
SENS. LOC.
9
Set Foam Class
All Display
Modules
Set at factory to Class B.
Changes Foam Class indicator on display.
SETUP / FOAM
CLASS
10
Foam Pump Type
Once using
any Display
Module
Set at factory to foam pump type shipped with the system.
Change ONLY if setting does not match with hardware.
SETUP / FOAM
PUMP TYPE
11
Foam Tank Size
Once using
any Display
Module
For systems equipped with Tankvision Pro. Set foam tank capacity
used to supply AccuMax system.
SETUP / FOAM
TANK TYPE
12
Tankvision Pro Address
Once using
any Display
Module
For systems equipped with Tankvision Pro. Set Tankvision Pro
address that identifies which foam type tank is used by AccuMax
SETUP / FOAM
GAUGE ADDR.
13
Set Date / Time
Once using
any Display
Module
Set date and time.
USER
SETTINGS / SET
DATE/TIME
Table 1. AccuMax System Setup Process