44
35
No data from MODEM
No data from MODEM connected via UART
interface
45
36
Acquire status alarm
Modem acquire failure status
46
37
Last acquire error status
Modem last acquire failure status
47
38
Radial MSE
Radial MSE is out of defined range
48
39
LDPC decoder stress
LDPC decoder stress is out of defined range
49
40
Tx ACM profile was changed
ACM profile was changed
50
41
RX carrier offset
Error in Rx carrier offset
51
42
No data from modem
temperature sensor
No data from modem temperature sensor
via I2C interface
52
43
Modem temperature fault
Modem temperature is out of defined
range
53
44
ATPC Tx power correction was
changed
ATPC Tx power correction was changed
54
45
Rollback initiate system CPU
restart ==>
System restart was called by rollback [Only
rising]
55
46
System CPU reset was WDT
initiated ==>
System restart was called by watchdog
[Only rising]
56
47
PM log flash write error
Error while writing pm log to flash
57
48
Command from interface
Message about command execution from
particular interface
58
49
Message of event
Informative message
59
50
E1/T1 interface
E1/T1 interface state was changed
60
51
Eth interface
No connection to Ethernet LAN port
61
52
AUX alarm in 1
AUX alarm 1 was enabled
62
53
AUX alarm in 2
AUX alarm 2 was enabled
63
54
AUX alarm in 3
AUX alarm 3 was enabled
64
55
AUX alarm in 4
AUX alarm 4 was enabled
65
56
No protection data from
alternate
If 1+1 protection is enabled and no data
from alternate (paired) device
66
57
Protection state was changed
Protection state was changed
67
58
Aggregation state was changed
Event of aggregation state change in
aggregation 2+0 configuration
68
59
Aggregation events
Event of aggregation 2+0 configuration
69
60
Keepalive ethernet switch reset
Ethernet switch does not respond and thus
is reset
5.1.3
Alarm Status Window
‘Status
Alarm status’ in navigation bar shows you all the current alarms.
Date and time represents the time the alarm appeared, so you can easily evaluate for how long
the alarm has been active. ‘Alarm gr.’ is the number of alarm group in which the specific alarm is
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015
83