Execute for both
” is available in “Main configuration” section during configuration of modem or
ATPC parameters for local and remote radio sides simultaneously. Connection between both
management CPUs must be established in order to complete successfully configuration execution for
both sides.
“
Rollback on
” feature is intended to maintain connectivity of the CFIP link by cancelling last
erroneous configuration changes and reverting to previous successful configuration used. Rollback
will activate only if you lose connection to WEB interface of CFIP PhoeniX after configuration changes
applied, and reverting process will take approx. 3 minutes.
After parameter value editing, when the focus from this object is removed, this parameter value edit
box may be highlighted in red, meaning that entered value is not valid.
If “
Execute configuration
” or “
Execute for both
” buttons are pressed, and one or several configuration
values edit boxes is/are highlighted in red, the user will see error message with the explanation text.
Figure 2.8
Web Interface - IP configuration page with numbering
2.3.6
Initial Configuration with Web GUI
IP settings of connected laptop should be in the same subnet as manageable CFIP in order to
observe it. Refer to Chapter 2.3.2 for further details. The next step is to connect to CFIP PhoeniX by
entering IP in the browser address line – which is by default 192.168.205.10. In case you are not sure
which side you are managing at the moment, you can try both default IP addresses.
When you are connected to the CFIP PhoeniX, you will see the window similar to the one shown in
Figure 2.6
.
To start simple configuration process, you must proceed with the configuration wizard which will
set up the main parameters of the link to make it work. So, the first step is to go to ‘
Configuration
Configuration wizard
’
as shown below in the
Figure 2.9.