Miscellaneous Controls in Web Graphic User Interface
These controls are located in the Navigation Panel under the “Tools” item.
6.1
Ethernet/Configuration files
This section allows working with CFIP configuration script.
The management module has RAM and EEPROM chips on-board. When CFIP is booted up,
bootstrap is loaded from the EEPROM into RAM. The bootstrap contains the parameters that were
previously stored in EEPROM using
write
and/or
cfg write
commands. These parameters are stored in
EEPROM in the form of script and during boot up, the script parameters are loaded into RAM. These
parameters can be freely changed in run-time, - changing the data in RAM. If the CFIP is shut down
without saving the current configuration (script) in EEPROM, the original configuration will be
restored from EEPROM during next boot-up.
Example of script can be observed on the screenshot below.
The script can be edited:
–
string can be added by simply entering required string (see Nr. 7 on the screenshot below) or by
executing command in CLI or in the appropriate Web GUI section (the script will be
supplemented with the new string or the instant string entry will be updated);
–
string can be deleted by entering appropriate line number (see Nr. 2 on the screenshot below) or
by using “
cfg delete
<string#>” in CLI.
The changes can be saved in EEPROM by pressing “Cfg write” button (see Nr. 3 on the screenshot
below) or by entering “
cfg write
” command in CLI.
Explanation of customization fields:
(!)
Note! The parameters that are not specified in the configuration script will have their default
values when the CFIP is restarted.
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•