Figure 4.41
Ethernet aggregation configuration for Slave
1.
Role
– choose
“Slave”
;
2.
Mode
– choose “Aggregation” for link aggregation 2+0 or “Protection” for link protection
1+1;
3.
Revertive mode
– in case of “enabled” setting link will automatically reconfigure back to 2+0
operation when unit/cable/link failure is resolved. In case of “disabled” setting link will
continue to operate in 1+0 mode; In order to activate 2+0 manually, it is necessary to press
“Change state: Active” button (7) on any of two Slave units.
4.
In “Slave aggregation/protection table” set the following:
a.
IP address of Master unit (directly connected to Slave unit
b
)
b.
IP address of Slave unit (you are configuring)
c.
Link ID for Master link (same Link ID should be set on second Master unit)
d.
Link ID for Slave link (same Link ID should be set on second Slave unit)
e.
LAN port number which will be used as Management port (connection to external
switch)
f.
LAN port number which will be used as Aggregation/Protection port (connection
with Master unit)
5.
Pressing
„Execute configuration”
applies changes made to the corresponding section only for
the local side CFIP PhoeniX. If
„Rollback on”
is selected, configuration will be reverted in case
of erroneous configuration changes applied;
6.
Writes to configuration file all the changes made on the whole page (command line –
cfg
write
);
7.
Change state: Active
– can be used to manually reactivate 2+0 aggregation mode if Revertive
mode was disabled and for some reason link reconfigured to 1+0
8.
System returned -
in case of error or incorrectly entered parameter value, or other problems
on the whole page – the info message is being shown here. Otherwise it says “Ok”.
4.8
VLAN Configuration
The VLAN configuration window provides configuration of port-based Ethernet Virtual Local Area
Networks (VLANs), allowing using up to 4095 different VLAN IDs. It is possible to assign 2 modes to
your VLANs – Trunk (VLAN tagged packets are passed through on egress and ingress directions) and
Access (VLAN tagged packets are untagged on egress direction).
In order to add VLAN tag to untagged packets on ingress direction, according “Default VLAN” (5)
should be specified. By default “Default VLAN” value on all ports is VLAN ID 1.
When upgrading from any firmware prior to 1.63.xx, “Default VLAN” VID 0 will be changed to VID
1, but if “Default VLAN” VID was other than “0”, it will remain the same.