LED
name
Description
ODU
Green –
OK
Yellow blinks –
ODU Tx mute.
Yellow –
Rx level alarm; ODU Temperature failure; IDU PSU to ODU state alarm.
Red
– Tx PLL error alarm; Rx PLL error alarm; ODU RX LOS; ODU TX LOS; ODU RX failure;
ODU TX failure; ODU Frequency failure.
Red blinks
– No data from ODU.
IDU
Green –
OK
Yellow –
IDU temperature fault; Main supply 48V failure; IDU PSU state alarm; PSU
temperature fault; Power supply voltage failure.
Red blinks
– No data from IDU temperature sensor; No data from main PSU IDU ADC; No
data from main PSU ODU ADC; No data from PSU temperature sensor; No data from
power supply ADC.
Modem
Green –
OK
Yellow –
Radial MSE; LDPC decoder stress; RX carrier offset.
Red
– Acquire status alarm; Last acquire error status.
Red blinks
– No data from MODEM.
System
Green
– OK after successful boot.
Green blinks
– System booting.
Yellow -
License expired.
Yellow blinks -
Invalid device license.
Red –
Boot failure or selftest failure.
2.5.2
Ethernet RJ-45 connector LED indications
LED color
Description
Yellow
ON
– link speed is 1000Mbps/s
OFF
– link speed is 100Mbps/s
Green
ON –
Ethernet link is up
Blinking –
activity on port’s egress/ingress directions
2.5.3
E1 RJ-45 connector LED indications
E1 port LED
(highlighted)
Color
Description
Green
(loop-back LED yellow
or off)
Indicates normal operation of the
channel, no problems with signal
reception.
Red
(loop-back LED yellow
or off)
Constant red indicates that E1 signal
is lost. If red flashes momentarily,
the bipolar violation (line code error)
was received from user equipment.
Blinking green and red
(loop-back LED yellow
or off)
AIS signal is being received from
user equipment.
Yellow loop-back LED
(loop-back switched
on)
When loopback LED is switched on,
analog, digital or remote loop-back
mode is active for that channel.
No LED is lit
Channel is switched off.
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.13
•
© SAF Tehnika JSC 2015
33