Figure 2.1
CFIP Phoenix IDU DC Power Cable Connector of type 2ESDV-02
After successful powering of PhoeniX IDU there are four ways to adjust and read settings and
operation parameters of the CFIP PhoeniX equipment:
1.
using Web terminal connected to the 10/100/1000Base-T Port,
2.
using Telnet terminal connected to the 10/100/1000Base-T Port,
3.
using NMS or SNMP terminal, connected to the 10/100/1000Base-T Port, or
4.
using ASCII console connected to the serial port.
2.1.1
Power protection port
Optionally CFIP PhoeniX IDU can be equipped with power protection port, which allows you to
interconnect 2 CFIP PhoeniX IDUs in 1+1 configuration for power interface redundancy functionality.
Interconnection between power protection ports is done with optional power protection cable (P/N
S0ACPR11).
Figure 2.2
CFIP Phoenix power protection port and cable (for IDU S0GIP*11)
2.1.2
Connecting CFIP PhoeniX IRFU to power source
CFIP PhoeniX IRFU can be powered via coaxial IF cable or using separate power supply, providing at
least 60W load power.
2.2
Resetting the CFIP PhoeniX
Depending on the method used, the user may reset the whole terminal or the management
controller individually, see table below for details.
Reset action unplugging power source.
Restarts both the multiplexer module and the management
module. Resets all management counters.
Resetting with
button in
Web GUI ‘Configuration
System
configuration’ window or using command
Restarts CPU of the management controller. Resets all
management counters.
(!)
Power protection port is available for CFIP PhoeniX IDU with P/N S0GIP*11
(!)
Note that pin 2 (‘
+’
) of the CFIP PhoeniX IRFU DC Power connector (
Figure 2.1
) is connected
to the IDU chassis ground internal to the IDU. Use of a power supply with an inappropriate
ground reference may cause damage to CFIP PhoeniX IRFU and/or the power supply.
CFIP PhoeniX Series TDM/IP Split Mount System Technical Description and Configuration Guide
•