7.2 The Setting Tool
Specification
Enclosure
IP67
Certification
EEx ia IIC T4 (intrinsically safe)
FM, INT SAFE, Class I & II Div 1 Groups A B C D E F G, T4A
CSA, Exia, Class I, II Div 1 Groups A B C D
Power supply
9V Battery (supplied and fitted)
Operating range
0.75m (from actuator display window)
Name
Instruction
1.
Q
Key*
Display next function down
2.
O
Key*
Display next function across
3.
-
Key
Decrease/change displayed function’s value or option setting
4.
+
Key
Increase/change displayed function’s value or option setting
5.
Key
Enter displayed value or option setting
* Pressing the two arrow keys together returns the actuator display to the position
indication mode
Infra-red local operation
(when enabled)
5. Key Stop
actuator
6. Key
Open
actuator
7. Key
Close
actuator
8. Infra-red Transmitter Window
Fig. 7 The Setting Tool
Setting Tool Battery Replacement
Battery status can be checked by looking at the Infra-red transmitter window while
depressing any Setting Tool button. A flashing red indicator should be seen.
Battery replacement must be carried out in a safe area. To replace the battery
remove the six caphead screws in the back of the Setting Tool. Remove the back
cover to expose the battery.
In order to maintain hazardous area certification fit only Duracell MN1604 or
Rayovac Alkaline Maximum NoAL-9V battery types. Refit cover ensuring red
indicator LED faces the transmitter window in the back cover.
When a button is depressed the Setting Tool transmits the relevant instruction to
the actuator by infra-red pulses and must therefore be directly in front of the
actuator indicator window and at a distance no greater than 0.75m.