Scale factor / K-factor (P013)
Level measurement
When the process value (PV) is a level measurement in meters, feet, or inches, this parameter
converts (scales) the level measurement into alternative units before being output. Enter a value
of 1.0 if alternative units are not required.
Volume measurement
When the PV is a volume measurement from a
standard non-linear-shaped
tank e.g. cylinder or
sphere, use this parameter to enter the volume of the ideal shaped tank (
).
When the PV is a volume measurement from a
regular-shaped
tank e.g. square or rectangular,
use this parameter to enter the volume change per unit of the base unit.
When the PV is a volume measurement from an
irregular-shaped
tank, use this parameter to
enter the maximum volume. See also the Special Plot section on
for defining the
irregu-
lar-shaped
tank.
Open channel measurement
When the PV is the flow rate in a
standard
open channel, use this parameter to enter the scale
factor (‘k’ term) in a flow rate calculation. See
for selecting a
standard flow profile.
When the PV is the flow rate in an
irregular-shaped
open channel, use this parameter to enter the
maximum flow rate. See also the Special Plot section on
for defining the
irregu-
lar-shaped
channel.
Field Communicator or AMS
To view or change the scale factor / k-factor:
1.
From the
Home
screen, select
2: Configure
.
2.
Select
2: Manual Setup
.
3.
Select
3: Profiling
.
4.
Select
4: Scale Factor P013
or
4: k-factor P013
,
depending on the Non-Linear Profile selected (see
).
5.
Input the new factor, and press “
ENTER
” to save it.
6.
Press “
SEND
” to update the transmitter.
Fast Keys
2, 2, 3, 4
Scale Factor P013
1
1
ESC
DEL
ENTER
HELP
w
s
q
a
z
Lock
Shift
@ &
á ü
x
e
d
c
r
f
v
t
g
b
y
h
n
u
j
m
*
-
+
/
.
0
7
4
1
8
5
2
9
6
3
i
k
o
l
FN
(Field Communicator Screen)
Содержание 3107
Страница 2: ......
Страница 4: ...Reference Manual 00809 0200 4840 Rev BA Title Page December 2014 ...
Страница 10: ...TOC vi Reference Manual 00809 0200 4840 Rev BA Table of Contents December 2014 Table of Contents ...
Страница 16: ...6 Reference Manual 00809 0200 4840 Rev BA Section 2 Transmitter Overview December 2014 ...
Страница 90: ...80 Reference Manual 00809 0200 4840 Rev BA Section 4 Configuration December 2014 Section 4 Configuration ...
Страница 144: ...134 Reference Manual 00809 0200 4840 Rev BA Appendix D Field Communicator December 2014 Appendix D Field Communicator ...
Страница 145: ......
Страница 146: ......
Страница 147: ......