Field Communicator or AMS
To use the simulation tool:
1.
From the
Home
screen, select
3: Service Tools
.
2.
Select
5: Simulate
.
3.
Select
1: Primary Variable
.
4.
Select
2: Change Mode
.
5.
Select a simulation mode e.g.
2: Run Up
.
6.
The simulation is now running, and Simulation
Enabled is “
ON
”.
7.
Monitor the parameters
Primary Variable (PV)
,
Current Output
, and
Percentage of
Current Output
on the LCD screen.
8.
When finished, change the mode to “
Normal
”.
Note
When messages appear, take appropriate action if needed and press “
OK
”.
Rosemount 3490 Series Control Unit
To use the simulation tool:
1.
From the
Main Menu
screen, select
SETUP
.
2.
Select the transmitter (e.g. “
Tx1: 3107
”).
3.
Select
SYSTEM
.
4.
Select
Simulation
.
5.
Select a simulation mode.
6.
When finished, select “
Quit
” to exit to the previous menu.
1. Simulation Enabled
2. Change Mode
3. Primary Variable D900
4. Current Output D906
5. Percentage Current D905
2. Change Mode
SAVE
HOME
HELP
OFF
35.0078 ft
14.40 mA
19.0 %
(
Field Communicator Screen Shown
)
SIMULATION
Esc=Quit =Edit
Normal
(Rosemount 3491 Screen)
Содержание 3107
Страница 2: ......
Страница 4: ...Reference Manual 00809 0200 4840 Rev BA Title Page December 2014 ...
Страница 10: ...TOC vi Reference Manual 00809 0200 4840 Rev BA Table of Contents December 2014 Table of Contents ...
Страница 16: ...6 Reference Manual 00809 0200 4840 Rev BA Section 2 Transmitter Overview December 2014 ...
Страница 90: ...80 Reference Manual 00809 0200 4840 Rev BA Section 4 Configuration December 2014 Section 4 Configuration ...
Страница 144: ...134 Reference Manual 00809 0200 4840 Rev BA Appendix D Field Communicator December 2014 Appendix D Field Communicator ...
Страница 145: ......
Страница 146: ......
Страница 147: ......