Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Operation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
77
7.7.1 Modifying of system parameters
If system parameters need to be changed, proceed as follows:
•
Press the <
System
> key when being in the measurement mode.
•
Press the <
modify setup
> key.
•
If a password is existing, the password inquiry appears.
Then type-in the valid password and confirm with <Enter>. Only then access to the system
settings is permitted.
If no password is existing, the password inquiry will not be called up.
•
With the <
arrow
> keys access the entry to be changed from the parameter list to the right
and change with the <+> / <-> keys.
•
With the <
save
> key store the entry or dismiss with <
cancel
>.
•
If a restart is required, the system will perform it automatically ( systems following serial
number 400059 / SW version 1.16 ).
It is recommended to note down all changes, in order to enable easy return to the previous settings
in case of doubt.
Pos: 58 /Schweissnaht/ Geräte/ SND40/8 Betrieb/Rundkö rpe r/Erstelle n und Bea rbeiten Me ssprogramme @ 0\mod_1165993833453_501.docx @ 2407 @ 2 @ 1
7.8
Creating and editing of measuring programs
In the measuring programs the parameters for detecting and positioning the weld seam are stored.
We recommend to create product specific / tool specific measuring programs, in order to consider
all variables (material, wall thickness, width of weld seam, etc.) which are important for optimal
detection.
For creating / editing a measuring program first insert a sample tube into the turn drive and with the
<
Program
> key change over to the ”
Setup – Program selection
” mode. There select an empty
program place or the program to be edited.
Note:
Creating of new programs can be simplified by copying of existing programs and
modifying them, if they are intended for similar tubes.
1.
With the key <
Edit program
> change over to the “
Setup – Test operation
“.
2.
Enter parameter ”
Description
“ and ”
Diameter
“ (only for initial editing).
3.
Enter parameter “
Rotation
“ or “
Speed
“ (coarse value).
4.
Enter parameter ”
Sensor signal
“:
When using the sensors NS9S, NS12S or the NSL sensors, select “
Leakage flux
”;
when using the sensors NS9-EC…, select ”
Leakage flux
“ or “
Eddy current
”;
when using the sensors EC…, select “
Eddy current
”.
5.
Press the <
Speed measurement
> key:
When measuring the speed, the parameter
„
Rotation
“ or “
Speed
“ should have a plausible
value.
In the visualisation of the signal there should
be 2 weld seam signals visible:
Fig. 43: Speed measurement
6.
Press the <
Start test job
> key.