Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Technical records
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
147
Minimal wiring of interface
Measuring procedure by external PLC
Note!
For externally triggering a measuring with IN0, a valid program must be selected (externally or via keyboard) and the unit
must be in ”
Automatic - Ready
“ condition.
Parallel Data Inputs
1)
IN0
/ Measuring Start
Parallel Data Outputs
1)
OUT2
/ Ready for measuring
OUT5
/ General fault
OUT7
/ Motor
t1: < 20 ms
t2: > 30 ms
t3: Depending on tube diameter
t4:
≥
0 ms
t5: > 30 ms
1)
Not mentioned inputs / outputs of the interface are not required for measuring.
2)
A ”HIGH“ signal at the
”General fault“
output indicates, that the weld seam might not be correctly positioned.
t1
t2
t4
t3
t5
2)