Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
System description
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
15
2.3.5 Rotary speed of the tube
The rate of tube turns is mostly determined by the cycle time. See previous chapter „Cycle time
and duration of weld seam detection“.
However, it may happen that a very short cycle time requires a very high tube rotation speed N.
This can lead to system-related limitations. To check use the formula below:
D
A
K
N
D
A
750
⋅
<
<
⋅
however > 5 rpm and < 300 rpm
N
= Rate of tube turns [rpm]
D = Tube Diameter [mm]
A = Scanning values per cm
(item in program parameter 5… 120)
K = 1.000.000
There are no restrictions if the rate of tube turns N is within the limits.
Important:
During the detecting procedure the rotation rate of the tube must be
constant.
2.3.6 Speed
At friction roller drive the speed of the surface / of the periphery is specified.
Whether system related limitations are observed can be checked using the following formula:
A
K
V
10
<
<
V
= Speed [mm/sec.]
A = Scanning values per cm
(item in program parameter 5… 120)
K = 50.000
There are no restrictions if the velocity V is within the limits.
Important:
During the detecting procedure the speed must be constant.