Manual
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
B0059001 / Rev. 2.3
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
65
6.3
Basic settings / Standard values
6.3.1 Program parameters
Standard values – Eddy current
Parameter
Standard value
Alternative
Application-specific
Standard
General data
Program number:
1
X
Description
X
Diameter [mm]:
30.0
X
Length [m]:
-
After-run [°]:
0
X
Rotation rate [rpm]:
-
Speed [mm/s]:
100
(X)
(X)
Analysis
Slip rate [%]
3.0
(X)
X
Weld seam width [%]:
3
(X)
X
Samples per cm:
30
X
Sensor signal:
Eddy current
X
Filter type:
Flank Extreme / SAF
Absolute
(X)
X
Detection grade:
good
(X)
X
Group:
-
Correlation factor:
-
Eddy current parameters
Low pass [Hz]:
Auto
High pass [Hz]:
Auto
Frequency [kHz]:
50.0
(X)
(X)
Phase [°]:
0
X
Signal type:
Y-component
Amount
X
Input gain [dB]:
20
(X)
Output AC voltage [V]:
20
X
DC voltage offset [mV]:
-
X
Y stretch:
1
X
Signal parameters
Signal gain:
20
X
Magnetization
Rel. magnetic flux [%]:
100
(X)
X
Transient time [ms]:
1500
X
Switch-off delay [ms]:
0
X
Indication parameters
Picture intervals:
5
X
7
not before software version 1.15