6.3.2 System parameters
Standard values – Eddy current / Leak flux
Parameter
Eddy current
Leak flux
Standard value
Alternative
Standard value
Alternative
Program version:
Language:
Product geometry:
Round material
Round material
Driving principle:
Constant
speed
Constant
turning rate
Constant
speed
Constant
turning rate
Max. rotation rate [rpm]:
300.06
300.06
Min. rotation rate [rpm]:
5.00
5.00
Max. speed [mm/s]:
3000
3000
Min. speed [mm/s]:
10
10
Angular resolution [°]:
1.0
1.0
Interval forming:
Time
Time
Time interval:
500 ms
500 ms
Path interval:
500 mm
500 mm
Path resolution [mm]:
1000
1000
Fieldbus:
off
off
Fieldbus address:
1
1
Fieldbus baud rate:
115
115
Inputs to logics:
255
255
Outputs from logics:
255
255
Selection test job:
KM
PLC
KM
PLC
Confirm mode:
yes
no
yes
no
Monitoring of outputs:
yes
no
yes
no
Monitoring of magnetizing current
yes
no
yes
no
Filter automatics:
off
on
off
on
Filter parameters:
5
5
Effective width of probe [mm]:
4
4
Monitoring of slip:
on
off
on
off
Statistics:
on
off
on
off