B0059001 / Rev. 2.3
Operation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
75
7.6.1 Generating Log files
The system can generate 3 different Log files:
1. Statistics.log
Generating this file can be switched on with system parameter <
Statistics on/off
>.
Example:
[STATISTICS]
GOOD = 148634
BAD = 552
SLIPPAGE = 168
[PROGRAM]
ACTIVE PROGRAM = 2
[ERROR]
CURRENT_POSITION = 17
ERROR1 = 0X00C
ERROR2 = 0X00C
ERROR3 = 0X00C
2. SNlog.1234
Generating this file can be switched on with system parameter <
SN file on/off
>
The file extension encrypts the current date (year*365 + month*31 + day). After 14 days the oldest
file will automatically be deleted. (Statement of signal-noise-ratio from SND version 1.17)
Here all messages are stored, which are shown in the status bar.
Example:
Weld seam detection good 14dB 10/04/07 09:47
Weld seam detection good 12dB 10/04/07 09:48
PM: AC overdrive 10/04/07 09:48
Weld seam detection not possible 0.9dB 10/04/07 09:49
...
3. Signal1.log
Shows the digital values of the measured tubes.
The file can be accessed with keys <
System
> <store
Job
>. There will be max. 10 files generated,
then the first file will be overwritten.
Example:
ProgNo 4, 14/02/07 23:53
Weld seam detection not possible 0.9dB
(inserted from SND version 1.17)
Original, Filter, Check
2503, 382, -83
1722, 180, -47
2424, 358, -61
1448, 127, -67
654, 26, -34
-1646, 165, -49
-1742, 185, -7
Pos: 56 /Schweissnaht/ Geräte/ SND40/8 Betrieb/Rundkö rpe r/System-Parame ter @ 0\mod_1186472739125_501.do cx @ 4443 @ 2 @ 1