Getting Started
R&S
®
Spectrum Rider FPH
83
User Manual 1321.1011.02 ─ 11
The R&S Spectrum Rider opens an entry box to enter the start frequency.
4. Enter a start frequency of 50 MHz.
5. Confirm the entry with one of the unit keys.
6. Select the "Stop" softkey at the "Measurement footer bar".
The R&S Spectrum Rider opens an entry box to enter the stop frequency.
7. Enter a stop frequency of 250 MHz.
8. Confirm the entry with one of the unit keys.
The R&S Spectrum Rider displays the frequency spectrum in the range from 50
MHz to 250 MHz. This frequency range visualizes the signal itself at 100 MHz and
the second harmonic at 200 MHz.
To measure the harmonic ratio, set the marker on the signal and a delta marker on
the second harmonic.
9. Press [MARKER] key.
The R&S Spectrum Rider sets a marker on the trace maximum. The trace maxi-
mum corresponds to the signal.
10. Select the "New Marker" softkey at the "Measurement footer bar".
The R&S Spectrum Rider activates a delta marker and places it on the next trace
maximum. This corresponds to the second harmonic.
The harmonic ratio is the vertical distance of the marker and the delta marker. The
R&S Spectrum Rider displays this value in the "Measurement result view".
Trying Out the Instrument
www.allice.de