Instrument Functions
R&S
®
Spectrum Rider FPH
104
User Manual 1321.1011.02 ─ 11
a) "Time interval"
You can define the duration of the time interval via the "Time Interval" menu
item.
b) "Limit failure"
Saves measurement data if a limit line is violated.
The R&S Spectrum Rider provides different modes for handling limit check fail-
ures. You can select one via the "Limits Save Mode".
● "Start On Failure": starts to save measurement data if a limit line is violated.
● "Stop On Failure": stops to save measurement data if a limit line is violated.
● "Save Only Failure": saves only the sweeps that actually fail a limit check.
c) "Distance interval"
Saves measurement data after you have covered a certain distance.
You can define the distance that is covered before the measurement data is
saved via the "Distance Interval" menu item.
d) "Every sweep"
Saves the data of all measurement sweeps that are performed.
Storage device
To use the "Save on Event" functionality, you need either an SD card or a USB stick to
store the data. The internal memory is probably not sufficient.
1. Press [SETUP] key.
2. Select "User Preference" softkey.
3. Select the "Recording Storage" menu item.
A drop-down menu to select the recording storage media opens.
4. Select the desired storage media.
Saving On Events
www.allice.de
Allice Messtechnik GmbH