Spectrum Analyzer Mode
R&S
®
Spectrum Rider FPH
169
User Manual 1321.1011.02 ─ 11
Test setup
The following illustrates the typical test setup to conduct the EIRP measurement.
Figure 6-11: Test setup for EIRP measurement
1. Connect the RF cable with the N coaxial connector to the RF input port.
2. Connect the antenna control cable to the USB interface of the R&S Spectrum Rider
via the USB adapter R&S HE300USB.
For a list of supported directional antennas, see
If the R&S Spectrum Rider detects the directional antenna, the accessory name
"HE300" or "HE400" is displayed in the
.
Start the measurement
1. Press [MEAS] key.
2. Select "Meas Mode" softkey.
The R&S Spectrum Rider opens a submenu to select the measurement mode.
3. Select the "EIRP" menu item.
The R&S Spectrum Rider performs the EIRP measurement and displays the result
in the EIRP info bar.
Performing Spectrum Measurements
www.allice.de