Remote Commands
R&S
®
Spectrum Rider FPH
421
User Manual 1321.1011.02 ─ 11
[SENSe:]DDEMod:FSK:OFFSet?
This command queries the measured frequency deviation of an FSK signal.
Prerequisites for this command: Select FSK demodulation
The numeric suffix at CALCulate is irrelevant for this command.
Parameters:
<Frequency>>
<numeric value>
Default unit: Hz
Example:
DDEM:FSK:OFFS?
Query frequency deviation.
Usage:
Query only
TRACe<1...2>[:DATA]?
[<arg0>]
This command queries the trace data of the current measurement.
It also transfers data from a file to a particular trace.
on page 335, you can set the data format.
on page 397, you can selects the
result display.
The numeric suffix at TRACe is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<arg0>
TRACe1 | TRACe2 | LIST | PHOLd | RAW
TRACe1
Queries the data of trace 1.
TRACe2
Queries the data of trace 2.
LIST
Queries the peak list of the measurement.
PHOLd
Queries the scanned peak hold list in the receiver mode mea-
surement.
RAW
Queries the raw FSK/ASK data in the analog demodulation
mode measurement.
The R&S Spectrum Rider returns 711 values. Each value corre-
sponds to one pixel of a trace.
The unit depends on the measurement and the unit you have
set with
UNIT<1...2>:POWer
.
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH