Spectrum Analyzer Mode
R&S
®
Spectrum Rider FPH
166
User Manual 1321.1011.02 ─ 11
●
R&S TSEMF-B1, 30 MHz to 3 GHz (order number: 1074.5719.02)
●
R&S TSEMF-B2, 700MHz to 6 GHz (order number: 1074.5702.02)
●
R&S TSEMF-B3, 9kHz to 200 MHz (order number: 1074.5690.02)
To work with the isotropic antenna, you need a USB adapter (TSEMF-CV, order num-
ber 1158.9250.02) to connect the antennas control cable via the USB interface of the
R&S Spectrum Rider.
Test setup
The test setup consists of an R&S Spectrum Rider and one of the isotropic antennas.
The necessary cables are provided with the antennas.
1 = Supported isotropic antenna (e.g. R&S TSEMF-B12)
2 = Isotropic RF connector
3 = USB adapter TSEMF-CV connecting to the isotropic antenna control cable
4 = USB port connector
1. Connect the RF cable with the N coaxial connector to the RF input port.
2. Connect the antenna control cable to the USB interface of the R&S Spectrum Rider
via the USB adapter TSEMF-CV.
If the R&S Spectrum Rider detects the isotropic antenna, the accessory name "Iso-
tropic Antenna" is displayed in the
.
Start the measurement
1. Press [MEAS] key.
2. Select "Meas Mode" softkey.
The R&S Spectrum Rider opens a submenu to select the measurement mode.
3. Select the "Isotropic Antenna" menu item.
Performing Spectrum Measurements