Modulation Analysis
R&S
®
Spectrum Rider FPH
252
User Manual 1321.1011.02 ─ 11
For more information frequency configuration, see
Chapter 6.1.1, "Measuring Basic
Chapter 6.1.2, "Measuring the Channel Power of
Continuously Modulated Signals"
Chapter 6.2, "Configuring Spec-
1. Press [FREQ] key.
2. Select "Center Freq" softkey.
The R&S Spectrum Rider opens an input field to define the center frequency input.
10.2.3
Amplitude Configuration
For more information on the amplitude configuration, see
Defining the position of the reference for ASK signals
In the graphical result displays, the reference position on the y-axis can be adjusted to
see the signal in greater details. By default, the maximum reference position is set to
100%.
1. Press [AMPT] key.
The R&S Spectrum Rider opens the amplitude menu.
2. Select the "Ref Position" menu item.
The R&S Spectrum Rider opens an input field to define the reference position in
term of percentage.
3. Enter the required value.
The R&S Spectrum Rider adjusts the y-axis and the position of the trace accord-
ingly.
Adjusting the display range for ASK and FSK signals
The R&S Spectrum Rider display range is divided into 10 grid sections, you can define
the deviation per grid section.
1. Press [AMPT] key.
The R&S Spectrum Rider opens the amplitude menu.
2. Select the "Deviation Per Division" menu item.
The R&S Spectrum Rider opens an input field to define the deviation.
3. Enter the required deviation.
The R&S Spectrum Rider adjusts the scale of the y-axis accordingly.
10.2.4
Sweep and Trigger Configuration
The sweep and trigger menu provides settings to control the measurement and the
way data is captured.
Digital Demodulation
www.allice.de
Allice Messtechnik GmbH