No. 35
Frequency Deviation, High Group (DTMF)
This parameter controls the acceptable frequency range for the high group DTMF tones. Increasing the value of this
parameter increases the frequency range. The frequency range will vary from one DTMF symbol to another. To increase or
decrease the parameter value, convert the increase/decrease into hex and add/subtract to/from the current value. (See
Section 13.3.)
Format:
16-bits, positive, twos complement
Equation:
Frequency Deviation ±(Increase/Decrease)h
Range:
0 to 7FFFh
Default Value:
0444h (CONF = 21h); 0260h (CONF = 90h, 92h, 94h or 98h)
No. 36
Negative Twist (DTMF)
This parameter controls the acceptable negative twist for the DTMF signals. Decreasing this parameter increases the
acceptable negative twist level. The twist will vary from one DTMF symbol to another. To increase or decrease the
parameter value, convert the increase/decrease into hex and add/subtract to/from the default value. (See Section 13.3.)
Format:
16-bits, positive, twos complement
Equation:
Negative Twist ±(Increase/Decrease)h
Range:
0 to 7FFFh
Default Value:
2800h (CONF = 21h); 0C2Eh (CONF = 90h, 92h, 94h or 98h)
No. 37
Positive Twist (DTMF)
This parameter controls the acceptable positive twist for the DTMF signals. Decreasing this parameter increases the
acceptable positive twist level. The twist will vary from one DTMF symbol to another. To increase or decrease the parameter
value, convert the increase/decrease into hex and add/subtract to/from the default value. (See Section 13.3.)
Format:
16-bits, positive, twos complement
Equation:
Positive Twist ±(Increase/Decrease)h
Range:
0 to 7FFFh
Default Value:
1420h (CONF = 21h); 3295h (CONF = 90h, 92h, 94h or 98h)
No. 38
Maximum Energy Hit Time (DTMF)
This parameter is a counter value which represents the number of sample times (the duration) of an allowed energy impulse
during the DTMF off-time measurement. A value of 0000h means no gain hits will be tolerated during the off time.
Format:
16-bits, positive, twos complement
Equation:
[(Desired Time in ms)(9.6)]h
Range:
0 to 7FFFh
Default Value:
0 (CONF = 21h); 0 (CONF = 90h, 92h, 94h or 98h)
No. 39
Number of Additional Flags (HDLC)
This parameter controls the number of flags between frames or at the end of the final frame. See Section 5.1.1 for more
information.
Format:
16-bits, positive, twos complement
Equation:
Desired number of flags - 1
Default Value:
0
Содержание RFX144V24-S23
Страница 64: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 3 30 1070 This page is intentionally blank...
Страница 92: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 5 10 1070 This page is intentionally blank...
Страница 110: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 7 8 1070 This page is intentionally blank...
Страница 156: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 9 34 1070 This page intentionally left blank...
Страница 170: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 11 8 1070 This page is intentionally blank...
Страница 178: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 12 8 1070 This page is intentionally blank...
Страница 184: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 13 6 1070 This page intentionally left blank...
Страница 197: ......