RFX144V24-S23 and RFX96V24-S23 Modem Designer’s Guide
1070
2-7
Table 2-3. MDP Hardware Interface Signal Definitions (Cont’d)
Label
I/O Type
Signal/Definition
~READ–ø2
IA
Read Enable–ø2. When ~EN85 is low (8085 bus selected), reading is controlled by the host pulsing ~READ
input low during the microprocessor bus access cycle. The read timing is:
Parameter
Symbol
Min.
Max.
Units
~CS Setup Time
TCS
0
–
ns
RSi Setup Time
TRS
10
–
ns
Data Access Time
TDA
–
45
ns
Data Hold Time
TDHR
10
–
ns
Control Hold Time
THC
10
–
ns
Phase 2 (ø2) Clock High
TP2CH
70
–
ns
Notes:
1.
~CS and ~READ must not both be active continuously.
2.
A read or write operation following a read operation must be delayed by at least 1 YCLK cycle.
~WRITE–R/~W
IA
Write Enable–R/~W. When ~EN85 is low (8085 bus selected), writing is controlled by the host pulsing ~WRITE
input low during the microprocessor bus access cycle. The write timing is:
Parameter
Symbol
Min.
Max.
Units
~CS Setup Time
TCS
0
–
ns
RSi Setup Time
TRS
10
–
ns
Control Hold Time
THC
10
–
ns
Write Data Setup Time
TWDS
20
–
ns
Write Data Hold Time
TDHW
10
–
ns
Phase 2 (ø2) Clock High
TP2CH
70
–
ns
Notes:
1.
A read or write operation following a write operation must be delayed by at least 2 YCLK cycles.
~IRQ1,
~IRQ2
OC,
OC
Interrupt Request. ~IRQ1 and ~IRQ2 interrupt request outputs may be connected to the host processor
interrupt request input in order to interrupt host program execution for immediate modem service. (The term,
“~IRQ,” refers to both the ~IRQ1 and ~IRQ2 output lines in the following discussion.) The ~IRQ output can be
enabled in DSP interface memory to indicate immediate change of conditions in the modem. The use of ~IRQ is
optional depending upon modem application.
The ~IRQ output structure is an open-drain field-effect-transistor (FET). The ~IRQ output can be wire-ORed
with other ~IRQ lines in the application system. Any of these sources can drive the host interrupt input low, and
the host interrupt servicing process normally continues until all interrupt requests have been serviced (i.e., all
~IRQ lines have returned high).
Because of the open-drain structure of ~IRQ, an external pull-up resistor to +5V is required at some point on the
~IRQ line. The resistor value should be small enough to pull the ~IRQ line high when all ~IRQ drivers are off
(i.e., it must overcome the leakage currents). The resistor value should be large enough to limit the driver sink
current to a level acceptable to each driver. If only the modem ~IRQ output is used, a resistor value of 5.6K
ohms, 20%, 0.25 W, is sufficient.
Содержание RFX144V24-S23
Страница 64: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 3 30 1070 This page is intentionally blank...
Страница 92: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 5 10 1070 This page is intentionally blank...
Страница 110: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 7 8 1070 This page is intentionally blank...
Страница 156: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 9 34 1070 This page intentionally left blank...
Страница 170: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 11 8 1070 This page is intentionally blank...
Страница 178: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 12 8 1070 This page is intentionally blank...
Страница 184: ...RFX144V24 S23 and RFX96V24 S23 Modem Designer s Guide 13 6 1070 This page intentionally left blank...
Страница 197: ......