Programming and Parameters
2-35
INPUTS/OUT
P
U
TS
Digita
l Inputs
361
362
363
364
365
366
[Digital In1 Sel]
[Digital In2 Sel]
[Digital In3 Sel]
[Digital In4 Sel]
[Digital In5 Sel]
[Digital In6 Sel]
(9)
Selects the function for the digital inputs.
Notes: Options 36-42 and 44&45 are
“Reserved”. Added options 43 and 46 for
firmware version 3.001.
(1)
Speed Select Inputs.
To access Preset Speed 1, set [Speed Ref x
Sel] to “Preset Speed 1”.
Type 2 Alarms - Some digital input
programming may cause conflicts that will
result in a Type 2 alarm. Example: [Digital
In1 Sel] set to “5, Start” in 3-wire control
and [Digital In2 Sel] set to 7 “Run” in2-wire.
Refer to
for information on
resolving this type of conflict.
(2)
When [Digital Inx Sel] is set to option 2
“Clear Faults” the Stop button cannot be
used to clear a fault condition.
(3)
Typical 3-Wire Inputs - Requires that only
3-wire functions are chosen. Including
2-wire selections will cause a type 2 alarm.
(4)
Typical 2-Wire Inputs - Requires that only
2-wire functions are chosen. Including
3-wire selections will cause a type 2 alarm.
See
for conflicts.
(5)
Auto/Manual - Refer to the Installation
Manual for details.
Default:
Default:
Default:
Default:
Default:
Default:
Options:
4
5
18
15
16
17
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15-17
18
19
20
21
22
23
24
25
26
27
28
29
30-33
34
35
36-42
43
44-45
46
“Stop – CF”
“Start”
“Auto/ Manual”
“Speed Sel 1”
“Speed Sel 2”
“Speed Sel 3”
“Not Used”
“Enable”
(6)(8)
“Clear Faults”(CF)
(2)
“Aux Fault”
“Stop – CF”
(8)
“Start”
(3)(7)
“Fwd/ Reverse”
(3)
“Run”
(4)(8)
“Run Forward”
(4)
“Run Reverse”
(4)
“Jog1”
(3)
“Jog Forward”
(4)
“Jog Reverse”
(4)
“Stop Mode B”
“Bus Reg Md B”
“Speed Sel 1-3”
(1)
“Auto/ Manual”
(5)
“Local”
“Acc2 & Dec2”
“Accel 2”
“Decel 2”
“MOP Inc”
(10)
“MOP Dec”
(10)
“Excl Link”
(10)
“PI Enable”
“PI Hold”
“PI Reset”
“Pwr Loss Lvl”
Reserved
“Jog 2”
“PI Invert”
“Reserved”
“Run Level”
(10)
“Reserved”
“Run w Comm”
(10)
(6)
Opening an “Enable” input will cause the motor to coast-to-stop, ignoring any
programmed Stop modes.
(7)
A “Dig In ConflictB” alarm will occur if a “Start” input is programmed without a “Stop”
input.
(8)
Refer to the Sleep Wake Mode Attention statement on
(9)
A dedicated hardware enable input is available via a jumper selection. Refer to
Installation Manual for further information.
(10)
Refer to
Selected Option Definitions – [Analog Outx Sel], [Digital Inx Sel], [Digital Outx
.
File
Gr
oup
No.
Parameter Name & Description
Values
Related
3
2
1
Auto Reference Source
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Reference A
Reference B
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Preset Speed 6
Preset Speed 7