3-12
Troubleshooting
Drive will not reverse motor direction.
Stopping the drive results in a Decel Inhibit fault.
Technical Support Options
Technical Support Wizards
If you are connected to a drive via DriveExplorer™ or DriveExecutive™,
you can run a Tech Support wizard to gather information that will help
diagnose problems with your drive and/or peripheral device. The
information gathered by the wizard is saved as a text file and can be emailed
to your remote technical support contact. (See
Call Tech Support on page 3-13
for more information.)
To run a Tech Support wizard in DriveExplorer, select
Wizards
from the
Actions
menu. In DriveExecutive, select
Wizards
from the
Tools
menu. Or,
click the
button. Follow the prompts to complete the wizard.
Cause(s)
Indication
Corrective Action
Digital input is not selected for
reversing control.
None
Check [Digital Inx Sel],
. Choose
correct input and program for reversing mode.
Digital input is incorrectly wired.
None
Check input wiring.
Direction mode parameter is
incorrectly programmed.
None
Reprogram [Direction Mode],
for
analog “Bipolar” or digital “Unipolar” control.
Motor wiring is improperly phased for
reverse.
None
Check for single phasing on the output of the
drive.
A bipolar analog speed command
input is incorrectly wired or signal is
absent.
None
1. Use meter to check that an analog input
voltage is present.
2. Check wiring.
Positive voltage commands forward direction.
Negative voltage commands reverse direction.
Cause(s)
Indication
Corrective Action
The bus regulation feature is
enabled and is halting deceleration
due to excessive bus voltage.
Excess bus voltage is normally due
to excessive regenerated energy or
unstable AC line input voltages.
Internal timer has halted drive
operation.
Decel Inhibit
fault screen.
LCD Status Line
indicates
“Faulted”.
1. See Attention statement on page
2. Reprogram parameters 161/162 to
eliminate any “Adjust Freq” selection.
3. Disable bus regulation (parameters 161 &
162) and add a dynamic brake.
4. Correct AC input line instability or add an
isolation transformer.
5. Reset drive.