2-32
Programming and Parameters
Inputs/Outputs File
File
Gr
oup
No.
Parameter Name & Description
Values
Related
INPUTS/OUTPUTS
Ana
log Inputs
320
[Anlg In Config]
Selects the mode for the analog inputs.
321
[Anlg In Sqr Root]
Enables/disables the square root function for each input.
322
325
[Analog In1 Hi]
[Analog In2 Hi]
Sets the highest input value to the analog
input x scaling block.
[Anlg In Config], parameter 320 defines if
this input will be –/+10V or 0-20 mA.
Note: The Min. value was changed from
4.000mA to 0.000mA for firmware version
3.001.
Default:
Min/Max:
Units:
10.000 Volt
10.000 Volt
0.000/20.000mA
–/+10.000V
0.000/10.000V
0.001 mA
0.001 Volt
323
326
[Analog In1 Lo]
[Analog In2 Lo]
Sets the lowest input value to the analog
input x scaling block.
[Anlg In Config], parameter 320 defines if
this input will be –/+10V or 0-20 mA.
Note: The Min. value was changed from
4.000mA to 0.000mA for firmware version
3.001.
Default:
Min/Max:
Units:
0.000 Volt
0.000 Volt
0.000/20.000mA
–/+10.000V
0.000/10.000V
0.001 mA
0.001 Volt
324
327
[Analog In1 Loss]
[Analog In2 Loss]
Selects drive action when an analog
signal loss is detected. Signal loss is
defined as an analog signal less than 1V
or 2mA. The signal loss event ends and
normal operation resumes when the input
signal level is greater than or equal to
1.5V or 3mA.
Default:
Options:
0
0
0
1
2
3
4
5
6
“Disabled”
“Disabled”
“Disabled”
“Fault”
“Hold Input”
“Set Input Lo”
“Set Input Hi”
“Goto Preset1”
“Hold OutFreq”
Anal
og Outputs
340
[Anlg Out Config]
Selects the mode for the analog outputs. .
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Current
0
=Voltage
x =Reserved
Bit #
Factory Default Bit Values
An1 0=V 1=mA
An2 0=V 1=mA
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Enable
0
=Disable
x =Reserved
Bit #
Factory Default Bit Values
Analog In 1
Analog In 2
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Current
0
=Voltage
x =Reserved
Bit #
Factory Default Bit Values
An1 0=V 1=mA
An2 0=V 1=mA