Power bus, operating voltage range
19.2…28.8V DC, Class 2
Power bus current (no load), max
50 mA
Input filter time, OFF to ON
(4)
0…126 ms (in 6 ms increments)
Input filter time, ON to OFF
Terminal base screw torque
See terminal base specifications
Indicators
1 yellow lock status indicator
1 green/yellow power status indicator
8 I/O channel status indicators
Keyswitch positions (left and right)
Key 1 = 8 (left); Key 2 = 2 (right)
Pilot duty rating
Not rated
North America temp code
T4
IEC temp code
T4
Enclosure type rating
None (open-style)
Wiring category
(5)
2 - on signal ports
Wire size
Determined by installed terminal block
Weight, approx.
62.4 g (2.2 oz)
Dimensions (HxWxD), approx. (without terminal block)
77 x 25 x 55 mm (3.03 x 0.98 x 2.17 in.)
(1) To comply with UL certification requirements, field power must be supplied from a single Class 2‐compliant power supply
Choosing a Power Supply on page 45
) which limits available field power to 100VA. Therefore, the aggregate current of outputs
per module is limited to a maximum set by the 100VA limit (unless derated further as shown) for applications that require UL
listing.
(2) Maximum power dissipation applies when using 28.8V DC module supply and maximum power dissipated with all eight outputs in
the ON state.
(3) Typical power dissipation applies when using 24V DC module supply and nominal power dissipated with all eight outputs in the ON
state.
(4) Input off-to-on filter time is the time from a valid input signal to recognition by the module. Input on-to-off time is the time from a
valid input signal to recognition by the module.
(5) Use this conductor category information for planning conductor routing. Refer to the Industrial Automation Wiring and Grounding
Guidelines, publication
.
Attribute
1734-OB8S Series B
Attribute
Value
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20…55 °C (-4…131 °F)
(1)
Temperature, nonoperating
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock):
-40…85 °C (-40…185 °F)
Temperature, surrounding air, max
55 °C (131 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):
5…95% noncondensing
Vibration
IEC 60068-2-6, (Test Fc, Operating)
5 g @ 10…500 Hz
Shock, operating
IEC 60068-2-27 (Test Ea, Unpackaged Shock) 30 g
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock) 50 g
Corrosives
1734-IB8S and 1734-OB8S Series B only: G2 (ISA S71.04)
Содержание Allen-Bradley 1734-IB8S
Страница 1: ...POINT Guard I O Safety Modules Catalog Numbers 1734 IB8S 1734 OB8S 1734 IE4S User Manual ...
Страница 4: ...4 Rockwell Automation Publication 1734 UM013J EN P July 2014 Summary of Changes Notes ...
Страница 10: ...10 Rockwell Automation Publication 1734 UM013J EN P July 2014 Table of Contents ...
Страница 14: ...14 Rockwell Automation Publication 1734 UM013J EN P July 2014 Preface Notes ...
Страница 22: ...22 Rockwell Automation Publication 1734 UM013J EN P July 2014 Chapter 1 POINT Guard I O Overview Notes ...
Страница 150: ...150 Rockwell Automation Publication 1734 UM013J EN P July 2014 Chapter 8 Replacing POINTGuard I O Modules Notes ...
Страница 180: ...180 Rockwell Automation Publication 1734 UM013J EN P July 2014 Appendix C Specifications Notes ...
Страница 186: ...186 Rockwell Automation Publication 1734 UM013J EN P July 2014 Appendix D Safety Data Notes ...
Страница 190: ...190 Rockwell Automation Publication 1734 UM013J EN P July 2014 Appendix E Configuration Parameters Notes ...
Страница 204: ...204 Rockwell Automation Publication 1734 UM013J EN P July 2014 Appendix G History of Changes Notes ...
Страница 211: ......