Installing network add-on cards in 2U SteelHead and SteelCentral xx80 appliances
12. Carefully turn over the riser bracket and insert it into the guide pins on the chassis (see
,
letter A).
Figure 3-26. Replacing the riser bracket in the chassis
13. Secure the riser bracket to the chassis with the two screws on the top of the riser brackets (see
, letter B) and the two screws on the back of the appliance (see
, letter B).
14. Replace the cover on the chassis (see
).
15. Connect the cables.
Note:
For appliances with storage units attached (that is, the SteelCentral AppResponse 8180), reconnect the SAS
cables to the same RAID cards prior to replacement.
16. Connect the power cords.
17. Power up the appliance and check the status lights.
To verify SteelHead network add-on cards
1. Connect to the SteelHead CLI.
For detailed information, see the
Riverbed Command-Line Interface Reference Manual
.
2. Enter enable mode. At the system prompt, enter the following command:
amnesiac > enable