102 | Installing NICs for SteelHead Virtual Edition Appliances
Configuring bypass cards for Hyper-V Server 2012 R2 and 2016
PCI addresses are displayed in the format
xx
:
yy
.
z
, where
xx
is the bus number,
yy
is the slot number,
and
z
is the function number.
2. Create an XML file for the SteelHead-v with entries to create the interface numbering.
Use the following guidelines when defining functions:
– Each SteelHead-v LAN/WAN pair must use the same bus number and the same slot number, but
must have a different function.
– If one interface of a LAN/WAN pair appears on function 0 in the guest VM, the other interface of
the pair must appear on function 1. If one interface of a LAN/WAN pair appears on function 2
inside the guest VM, the other interface must appear on function 3.
– For a 4 port card, 0,1,2, and 3 are the only allowed values the function can take.
– For a 2 port card, 0 and 1 are the only allowed values the function values can take.
The following XML example configures PCI values 04:00.0, 04:00.1, 04:00.3, and 04:00.4 so that the
SteelHead-v names the left-most pair of interfaces on the bypass card inpath0_0 and the right-most pair
1_0. The parts of the code that are in bold indicate the values to enter:
– The function values inside the source XML tags (0x2, 0x3, 0x0, and 0x1, respectively) correspond
to the function values in the PCI ID on the host.
– The slot and function values outside of the source XML tags (5 and 0x00, 5 and 0x01, 6 and
0x00, and 6 and 0x01 respectively) correspond to the LAN/WAN pair values in the SteelHead-v.
<hostdev mode="subsystem" type="pci" managed="yes">
<source>
<address type="pci" domain="0x0000" bus="0x04" slot="0x00" function="
0x2
"/>
</source>
<address type="pci" domain="0x0000" bus="0x0" slot="
5
" function="
0x00
"
multifunction="on"/>
</hostdev>
<hostdev mode="subsystem" type="pci" managed="yes">
<source>
<address type="pci" domain="0x0000" bus="0x04" slot="0x00" function="
0x3
"/>
</source>
<address type="pci" domain="0x0000" bus="0x0" slot="
5
" function="
0x01
" />
</hostdev>
<hostdev mode="subsystem" type="pci" managed="yes">
<source>
<address type="pci" domain="0x0000" bus="0x04" slot="0x00" function="
0x0
"/>
</source>
<address type="pci" domain="0x0000" bus="0x0" slot="
6
" function="
0x00
"
multifunction="on"/>
</hostdev>
<hostdev mode="subsystem" type="pci" managed="yes">
<source>
<address type="pci" domain="0x0000" bus="0x04" slot="0x00" function="
0x1
"/>
</source>
<address type="pci" domain="0x0000" bus="0x0" slot="
6
" function="
0x01
" />
</hostdev>
Configuring bypass cards for Hyper-V Server 2012 R2 and 2016
Complete this procedure to configure a bypass card for SteelHead-v appliances running Hyper-V Server
2012 R2 or 2016. Bypass cards are supported on Hyper-v from RiOS 9.7 or later.