Installing Network Cards in xx80 Appliances | 33
Installing network add-on cards in 1U xx80 appliances
18. Secure the add-on card holder with the two screws.
Figure 3-11. Securing the add-on card holder
19. Replace the cover on the chassis. For details, see
.
20. Connect the power cords.
21. Connect the cables.
22. Power up the appliance and check the status lights.
For details on the status lights, see
Appendix A, “Network Card Status Lights for SteelHead and
SteelCentral xx80 Appliances.”
To test SteelHead network add-on cards
1. Connect to the SteelHead CLI.
For detailed information, see the
Riverbed Command-Line Interface Reference Manual
.
2. Enter enable mode. At the system prompt, enter the following command:
amnesiac > enable
amnesiac #
3. Verify that the add-on card is correctly installed.
For example, to verify the add-on cards on a SteelHead, at the system prompt enter the following
command: