Installing Network Cards in xx80 Appliances | 37
Installing network add-on cards in 1U xx80 appliances
15. Connect the cables.
16. Power up the appliance and check the status lights.
For information about the status lights, see
Appendix A, “Network Card Status Lights for SteelHead
and SteelCentral xx80 Appliances.”
Enabling 10-GbE NICs in the 1U NetProfiler 4280-DP
and Flow Gateway 2280 appliances
For the Two-Port 10-GbE NIC to function correctly in the NetProfiler 4280-DP and SteelCentral Flow
Gateway 2280 appliances, you must disable the 1-GbE Primary and AUX ports and enable the 10-GbE
NIC Primary and AUX interfaces.
Important:
These instructions apply only to the Two-Port 10-GbE Fiber SFP+ NIC (NIC-1-010G-2SFPP) installed in
the NetProfiler 4280-DP and Flow Gateway 2280 appliances.
To enable the 10-GbE NIC interfaces on the NetProfiler 4280-DP and Flow Gateway 2280 appliance
1. After you have installed the 10-GbE NIC and racked the appliance, power it on. For details, on
installing NICs, see
“Installing network add-on cards in 1U SteelCentral xx80 appliances” on page 34
2. Connect to the appliance using the console port. (Since you are modifying the appliance interfaces,
we recommend you connect via the console port rather than SSH.)
3. Log in to the appliance as user:
mazu
, password: <password set for the device>
4. To verify that the 1-GbE NIC is present but not enabled, run this command:
sudo mazu-reconfig --get --use-addon-nic
The system returns:
found=true, enabled=false
5. If bonding of the 1-GbE interfaces is currently enabled, run the following command, otherwise, go
to
sudo mazu-reconfig --set --bond-dp-interfaces false
Important:
Do not perform this step if you are enabling the 10-Gbe NIC interface in the Flow Gateway 2280
appliance.
6. To enable the 10-GbE NIC interfaces, run this command:
sudo mazu-reconfig --set --use-addon-nic true
7. Reboot the appliance.
The 10-GbE NIC interfaces are now enabled and configurable as Primary and AUX in the web UI or the
CLI. The 1-GbE NIC Primary and AUX ports are disabled by this process.
Содержание SteelCentral AppResponse 2170
Страница 8: ...8 Contents ...
Страница 16: ...16 Getting Started Troubleshooting ...
Страница 166: ...166 NIC Status Lights for xx60 xx55 and xx50 Appliances NICs for Series xx50 platforms ...