RIGOL
2
.
Set up the channel bandwidth limit
To use CH1 as an example, input a signal that contains high frequency component.
Press CH1
→
BW Limit
→
OFF , to set up bandwidth limit to “OFF” status. It will pass
the high frequency component in the signal and the oscilloscope is set to full
bandwidth.
The waveform is displayed as Figure 2-4:
Set off bandwidth
Figure 2-4
Press CH1
→
BW Limit
→
ON, to set up bandwidth limit to “ON” status. It will reject
the frequency component higher than 20MHz.
The waveform is displayed as Figure 2-5:
Copyright 2004 Rigol Electronic
2-5
Bandwidth
limit symbol
Figure 2-5
Set bandwidth
limit to 20M
User Manual for DS5000 Series