16
9
CAUTION
Stick the provided
WARNING
Label and Lighting
Instructions to the front of the boiler casing if the closet
or alcove sides are less than 6” (150 mm) from the boiler
right side. Doing so will make the Lighting Instruction and
WARNING
Label visible for the appliance in an Alcove or
Closet.
Alcove Installations
Alcove installations have the same minimum clearances as
closet installations, except the front must be completely open
to the room at a distance no greater than 18 in. [457 mm] from
the front of the boiler and the room is at least three (3) times the
size of the alcove. Provided these conditions are met, the boiler
requires no extra ventilation air openings to the space.
Residential Garage Installations
When installed in a residential garage, mount the boiler
a minimum of 18 in. [457 mm] above the floor. Locate or
protect the boiler so it cannot be damaged by a moving
vehicle. Check with your local authorities for other pos-
sible regulations pertaining to the installation of a boiler
in a garage.
6.2
Before locating the Family PRO boiler
Check for nearby connections to:
− System water piping
− Venting connections
− Gas supply piping
− Electrical power
Check area around boiler. Remove any combustible materials,
gasoline and other flammable liquids.
9
WARNING:
Failure to keep boiler area clear and free of
combustible materials, gasoline and other flammable
liquids and vapors can result in severe personal injury,
death or substantial property damage.
The Family PRO must be installed so that gas control system
components are protected from dripping or spraying water or
rain during operation or service.
If the new Family PRO is to replace an existing boiler, check for
and correct any existing system problems such as:
− System leaks
− Incorrectly-sized expansion tank
− Lack of freeze protection in the heating system causing the
system and boiler to freeze and leak
− Excessive glycol which will affect the boiler system operation.
6.3
Clearances for service access
See “5.5 Dimensions and connections” page 15 for
recommended service clearances. If you do not provide the
minimum clearances shown, it might not be possible to service
the boiler without removing it from the space.
Recommended Minimum service clearances
6 BEFORE INSTALLATION
R
strongly recommends that this manual be reviewed
thoroughly before installing your Family PRO boiler. Please review
section “3 Safety” page 4 before installing the boiler. Factory
warranty does not apply to boilers that have been improperly
installed or operated.
Installation and service must be performed by a qualified
installer, service agency or gas supplier. If, after reviewing this
manual, you still have questions which this manual does not
answer, please contact or your local
R
distributor or Riello
Technical Support at 1(800)474-3556. Thank you for purchasing
this
R
product. We hope you will be satisfied with the high
quality and durability of our equipment.
6.1
Installations must comply with:
− Local, state, provincial, and national codes, laws, regulations
− and ordinances.
− National Fuel Gas Code, ANSI Z223.1/NFPA 54 – latest edition.
− National Electrical Code.
− For Canada only: CAN/CSA B149.1 Installation Code, CSA C22.1
Canadian Electrical Code Part 1 and any local codes.
Family PRO boiler must be installed indoors in a dry location
where the ambient temperature must be maintained above
freezing and below 100°F [38°C]. All boiler components must be
protected from dripping, spraying water, or rain during operation
and servicing. Consider the proximity of system piping, gas and
electrical supply, condensate disposal drain, and proximity to
vent termination when determining the best boiler location.
The boiler is both for closet and alcove installation.
Closet Installations
CLOSET INSTALLATION
“
“
“
0”/0 mm between the back of the unit and the wall
13 3/4"
5 7/8"
29 1/8"
2 5/16"
6 15/16"
18 in.
7 7/8
“
200 mm
1”
25 mm
6” *
150 mm
* Service clearances on the right side of the boiler can be decreased up to 1” (25 mm) if the provided
WARNING
Label and Lighting Instructions have been stuck to the front of the boiler casing
Содержание Family PRO 42 IS