Whenever a “NEW” configuration is selected, proceed as follows:
- select user interface functionality:
ON BOARD: if the user interface is used only as a system
interface and not as a thermostat
AMBIENT: if the user interface is used as a system interface and
also a thermostat of the zone where it is installed
ON BOARD
AMBIENT
WHERE IS
THE REC10 INSTALLED?
BOILER
ON BOARD
WHERE IS THE REC10 INSTALLED?
AMBIENT
BOILER
- select the type of boiler INSTANTANEOUS (if the boiler is the
Family PRO KIS, combination boiler)
PLANT
CH ONLY
INSTANTANEOUS
HW TANK
SELECT THE PLANT
CONFIGURATION
INSTANTANEOUS
HW TANK
CH ONLY
SELECT THE PLANT CONFIGURATION
PLANT
- For Family PRO IS select the type of boiler choosing
between:
- CH ONLY: when the boiler doesn’t manage domestic hot
water (case A)
- HW TANK: when the boiler manages an indirect tank.
NOTE: in this case you will be asked to specify the type
of hot water request (AQUASTAT - case B; or INDIRECT TANK
SENSOR - case C)
If selected a HW tank with probe, is required if there is also to
manage a solar system: answer NO to this question
PLANT
CH ONLY
HW TANK
INSTANTANEOUS
SELECT THE PLANT
CONFIGURATION
INSTANTANEOUS
HW TANK
CH ONLY
SELECT THE PLANT CONFIGURATION
PLANT
- select the type of domestic hot water FLOW METER
PLANT
FLOW SWITCH
PLANT
PLANT
FLOW METER
PLANT
PLANT
FLOW METER
FLOW SWITCH
- Once the guided procedure has finished, the user
interface will go to the initial screen.
Continue with the configuration as follows:
- access the technical parameters as explained in the
section “11.6 Access to the technical parameters”, using
the installer password “018”
WARNING
: The parameters
accessed by using this parameter should only be adjusted
by a qualified service technician. Failure to comply may
result in substantial property damage, severe personal
injury or death
- select PARAMETERS with the “up” and “down” buttons,
confirming the selection by pressing the “ENTER” button
Then proceed with the reprogramming of the boiler,
carrying out the operations described in the section”11.7
Programming the boiler”. “It is possible to return to the start
page at any time by continuing to press the “BACK” button,
for at least 2 seconds.”continuing to press the “BACK” button,
repeatedly, for at least 2 seconds at a time.
11.29
Replacing the front control MASTER
The system’s configuration needs to be carried out by a
professionally qualified personnel.
When replacing the front control MASTER, at the subsequent
restart it displays an initial screen with the firmware
version.
Pressing “ENTER” starts a guided procedure for configuring
the system, see section “11.28 System configuration”. Follow
the procedure and carry out the FROM MAIN PCB type of
configuration.