4 PRODUCT RECEIPT
On receipt of your boiler it is suggested that you visually check for
external damage to the shipping package.
If the package is damaged, make a note to that effect on the Bill of
Lading when signing for the shipment.
− Remove the boiler from the shipping packaging.
− Report any damage to the carrier immediately.
− On occasion, items are shipped loose.
− Be sure that you receive the correct number of packages as
indicated on the Bill of Lading.
− Claims for shortages and damages must be filed with the carrier
by consignee.
− Permission to return goods must be received from the manufacturer
or your local
R
distributor prior to shipping. Goods returned to
the factory without an authorized Returned Goods Receipt number
will not be accepted. All returned goods are subject to a restocking
charge.
− When ordering parts, you must specify the model and serial
number of the boiler.
− When ordering under warranty conditions, you must also specify
the date of installation.
− Purchased parts are subject to replacement only under the
manufacturer’s warranty. Debits for defective replacement parts
will not be accepted and will be replaced in kind only per
R
standard warranty.
4.1
Model Identification
The model identification number and boiler serial number are found
on the boiler rating plate located on the bottom side of the unit.
Also the boiler serial number can be found on the back page of this
manual and on the front of the boiler casing.
4.2
Boiler box content
Component
Qty
1
Condensing gas boiler
1
2
Wall bracket
1
3
Pressure relief valve ASME
1
4
Condensate check valve
1
5
Gas cock
1
6
Condensate check valve gasket
1
Pressure relief valve gasket
1
Gas cock gasket
1
7
Strain relief for secondary high voltage connexion:
- Family KIS
- Family IS
1
2
8
Set of documents for appliance
1
9
Vent adaptor Ø 3” (80 mm), L=6” (155 mm) for concentric
Ø 3/5” (80/125 mm) - see section 8.8 fig. 4
1
10
Vent adaptor Ø 2” (60 mm), L= 5 5/16” (135 mm) for
concentric Ø 2/4” (60/100mm) - see section 8.8 fig. 1
1
11
Outdoor temperature sensor
1
Paper template (see “7.2 Boiler template”)
1
12
Lighting Instructions (see Section 5.5-6)
1
WARNING
Label (see Section 5.5-6)
1
LP Gas Conversion Sticker
1
1
2
33
4
5
6
7
10
8
12
11
4.3
Installation at elevation
Rated inputs are suitable for up to 10,000 ft (3048 m) elevation (see
technical data table).
No hardware changes are required to the boilers for installations up to
10,000 ft (3048 m) (adjustments are required).
For additional settings on high altitude installations refer to your local
R
distributor.
5 INTRODUCTION
The FAMILY PRO boilers have a new ACC (Active Combustion Control)
system.
This new control system ensures functionality, efficiency and low
emissions under any conditions.
The ACC system uses an ionization sensor (flame sensor)immersed in the
burner flame, whose information allows the control board to operate
the gas valve that regulates the fuel.
This sophisticated control system provides the auto-regulation of the
combustion, so there is no need for an initial calibration; however, it
is recommended (required in some jurisdictions) that a combustion
analysis is performed during initial start-up and annual maintenance.
The ACC system is able to adapt the boiler to operate with different gas
compositions, different air inlet and exhaust vent lengths and different
altitudes (within the specified design limits).
The ACC system can also perform an auto-diagnostic operation that locks
out the burner before the permitted upper emission limit is exceeded.
FAMILY PRO
is a wall hung fan assisted room-sealed condensing boiler.
T
he
FAMILY PRO
combi is a direct vent, CAT IV wall mounted boiler for
heating and prodution domestic hot water.
T
he
FAMILY PRO
heating only is a direct vent, CAT IV wall mounted
boiler that is able to operate as follows:
-
EXAMPLE A:
heating only with no external indirect tank connected.
The boiler does not provide domestic hot water.
-
EXAMPLE B
: heating only with an external indirect tank managed
by a thermostat: in this condition, the boiler delivers hot water
to the water tank whenever a demand is made by the relative
thermostat.
-
EXAMPLE C:
heating only with an external indirect tank (available
by request) managed by a temperature sensor for the production
of DHW. If the water heater is not supplied by our company, make
sure that the relative indirect tank sensor (NTC sensor) has the
following characteristics: 10 kOhm at 77⁰°F (25⁰°C), B 3435 ±1%.
These appliances are designed for use with a sealed system only;
consequently they are not intended for use on power vented systems.
This manual is an integral part of the appliance. It is therefore necessary
to ensure that the manual is handed to the person responsible for the
property in which the appliance is located/installed. A replacement
copy can be obtained from www.riello.com.
IMPORTANT
It is the law that all gas appliances are installed by a competent person.
It is in your own interest and that of safety to ensure that the law is
complied with.
− The installation must conform to the requirements of the authority
having jurisdiction or, in the absence of such requirements, to the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 Where required by the
authority having jurisdiction, the installation must conform to the
Standard for Controls and Safety Devices for Automatically Fired
Boilers, ANSI/ASME CSD-1.
− The installation should conform with CAN/CSA B149.1 INSTALLATION CODE
and/or local installation Code, plumbing or waste water codes and
other codes as applicable.
− Clearances from combustible material must be strictly adhered to.
− Manufacturers instructions must NOT be interpreted in anyway as
overriding local regulations.
Massachusetts:
Boiler installation must conform to Commonwealth of Massachusetts
code 248 CMR which includes but is not limited to:
• Installation by licensed plumber or gas fitter.
In the state of Massachusetts:
− This product must be installed by a licensed plumber or gas fitter.
− When flexible connectors are used, the maximum length shall not
exceed 36 in. (914 mm).
− When lever type gas shutoffs are used they shall be T−handle type.
− The use of copper tubing for gas piping is not approved by the state
of Massachusetts.
Gas boilers manufactured on or after May 1, 2017 are not permitted
to be used in Canada for heating of buildings or structures under
construction.