50
an ambient thermostat, ensure that the thermostat or timer
is “active” and set correctly ~68°F (~20°C)
- Then set the boiler for HEATING AND HOT WATER selecting the
STATE menu on the front control and then BOILER, based on the
season and the type of operation selected.
18/05/2013
12:17
MENU
INFO
SET
FRI
PLANT
HOT WATER TEMPERATURE
STATE
107
°F
18.85 psi
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
BOILER
STATE
MAIN ZONE
BOILER
MAIN ZONE
STATE
−
BOILER
OFF
HEATING AND HOT WATER
HOT WATER ONLY
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
When there is a heat request and the boiler has ignited the “
” icon appears on the display. The boiler will start-up and
continue working until the set temperatures are reached,
after which it will then go back to standby.
AIR PURGE CYCLE FUNCTION
NOTICE
: Each time the boiler is started up an automatic air purging
cycle is carried out, lasting 4 min (6min for heating only model).
When the AIR PURGE CYCLE is in progress, all heat requests are
inhibited and a sliding message at the foot of the page appears
on the main page of the front control.
- In this condition the green and red LEDs light up alternately
for 0.1 sec with a pause of 0.5 sec and 1 sec between one
ignition and another.
X17
X14
1
1
X23
X16
X2
X21
X8
X13
X19
X9
X25
X11
X18
X22
1
1
1
1
1
1
1
1
6
1
5
12
10
4
3
5
4
6
5
6
X15
X1
X4
X6
1
3
1
5
1
2
1
6
X3
X7
arancione
E.R.
F2=4A T
CN1
X10
A9
SW1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20
- A B + TA TBOL TBT SE OT+ SBOL X1
X2
9 10
7 8
5 6
1 2
141516 17
nero (RT)
nero (RT)
rosa (OT+)
rosa (OT+)
arancione (ES)
arancione (ES)
6
1
1
2
5
1
rosso (+)
giallo (B)
arancione (A)
nero (-)
giallo (B)
nero (-)
rosso (+)
arancione (A)
bianco (TBT)
bianco (TBT)
(OT+)
(ES)
(TBT)
(RT)
+
-
A
B
REC
X11
X14
X25
M20
Utilizzare contatto privo di tensione
Voltage free contact input
X1
2
1
3
5
4
rosa
blu
P
N L
F= 3.15A F
230 V
M3
F
blu
marrone
marrone
marrone (+)
blu (-)
PWM
marrone
blu
marrone
blu
VALVOLA GAS
1 2
4
3
OPE
OPE
1
3
X8
M4
230 V
ausiliario
blu
marrone
marrone
6
3
1
2
4
5
blu
TSC2
blu
EA
marrone
giallo/verde
N
F
X6
3
1
2
marrone
X15
blu
V Hv
1
2
rosso (+)
blu (HS)
rosa (PWM)
grigio (-)
X13
V Lv
1
4
bianco bianco
S.M.
-t°
-t°
S.R.
rosso
rosso
-t°
S.F.
grigio
grigio
giallo
T.L.A.
blu
blu
1
12
giallo
X9
Non
usato
1
4
2 3
1
4
2 3
verde A1)
rosso (A2)
rosso (A2)
verde A1)
arancione (K2)
arancione (K2)
bianco(K1)
bianco(K1)
X10
J1
BE20
4
3
2
1
5
rosso blu viola bianco
3V
X12
grigio grigio
viola
viola
rosso rosso
nero (alim.)
blu (sign.)
marrone (-)
S.S.
MOD
T.P.
1
3
1
X19
10
F.L.
C.S.A.
marrone
blu
5
3
1
2
4
X4
combustion analysis button SW1
NOTICE
: The AIR PURGE CYCLE can be interrupted beforehand
by removing the cap from the control board cover and
pressing the combustion analysis button SW1 or from the
TECHNICAL menu of the front control in the following way:
- access the technical parameters as explained in the
section “11.6 Access to the technical parameters”
- select AIR PURGING CYCLE with the “up” and “down”
buttons, confirming the selection by pressing the
“ENTER” button
−
CALIBRATION
RANGE RATED
COMBUSTION ANALYSIS
ANTI-LEGIONELLA
AIR PURGING CYCLE
TECHNICAL
INSTALLER
AIR PURGING CYCLE
CALIBRATION
COMBUSTION ANALYSIS
ANTI-LEGIO
RANGE RATED
INSTALLER
TECHNICAL
select STOP FUNCTION with the “up” and “down” buttons,
confirming the selection using the “ENTER” button.
AIR PURGING CYCLE
STOP FUNCTION
INSTALLER
DISABLE FUNCTION
ENABLE FUNCTION
STOP FUNCTION
ENABLE FUNCTION
DISABLE FUNCTION
AIR PURGING CYCLE
INSTALLER
T
he front control will briefly display a wait message after
which, you will automatically be taken to the main screen.
18/05/2013
12:17
MENU
INFO
SET
86
°F
FRI
HOT WATER TEMPERATURE
STATE
PLANT
MENU
STATE
SET
INFO
PLANT
HOT WATER TEMPERATURE
FRI
HOT WATER ONLY
: by selecting the HOT WATER ONLY
operating mode in the STATE menu and then BOILER, just
the domestic hot water will be activated. The user interface
normally displays the temperature of the domestic hot
water supplied by the boiler.
With the FAMILY PRO IS boilers the function is active only with an
indirect tank.
The user interface normally displays the temperature of the
domestic hot water stored in the indirect tank (only when
using an indirect tank sensor).
When using an indirect tank with aquastat or a domestic hot water
request in progress, the boiler delivery temperature is displayed.
BOILER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
HEATING AND HOT WATER
/
: by selecting HEATING AND
HOT WATER in the STATE menu and then BOILER, the heating
and domestic hot water functions are activated. The
front control normally displays the domestic hot water
temperature unless there is a heating request in progress,
in which case the boiler’s outlet temperature is displayed.
Содержание Family PRO 42 IS
Страница 75: ...75 ...