Vedolux 30

1 3 1 2 1 6  V 3 0   e n _ m c s   r e v 1

Содержание Vedolux 30

Страница 1: ...Installation operation and maintenance Firewood boiler Vedolux 30 131216 V30 en_mcs rev1...

Страница 2: ...at you must or must not do in order to avoid personal injury Tells you what you must or must not do in order to prevent damage or disturbance to the component the burner the process or the surrounding...

Страница 3: ...3 V RMEBARONEN VEDOLUX 30 To be completed when the Vedolux 30 is installed Serial number Installation date Installer Tel Other Notes...

Страница 4: ...rewood is added Flue cleaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round...

Страница 5: ...drop 45 mBar 20 C 1 13 m h 58 mBar 10 C 1 46 m h Weight empty filled with water 290 390 kg kg Volume 100 litre Design pressure 1 5 bar Test pressure 2 15 bar Pressure drop water flow 0 54 l s 10 mbar...

Страница 6: ...boiler is supplied with an angled flue pipe a flue pipe running up from the steel pipe is available as an accessory Fasten the flue pipe to the flange on the boiler using the 4 x M8 screws supplied wi...

Страница 7: ...il this must be supplemented with a STW STW thermal discharge safety device is used for limiting the temperature by opening a valve normally by circa 97 C and letting cold water enter the cooling coil...

Страница 8: ...firewood is burnt out and the flue gas temperature falls below the value set for the thermostat 21 the fan and charging pump stop running If the boiler temperature exceeds 105 C the overheating protec...

Страница 9: ...n moisture instead of drying out Ideally the wood should be kept under a roof but in a place where the sun and wind can help dry it The best place for final drying is the boiler room for 2 3 weeks bef...

Страница 10: ...ing wood you must open the bypass damper before opening the firewood hatch Only add more firewood when all that is left of the previous load is a layer of embers Constantly topping up with the occasio...

Страница 11: ...it is time for cleaning is to check the flue gas ther mostat It is a good idea to clean the boiler if the flue gas tempera ture is approx 25 C higher than the temperature in a clean boiler Open the c...

Страница 12: ...hest points in the system the static head If the difference is 5 metres the pressure is 0 5 bar if it is 10 metres the pressure is 1 bar The necessary pressure in the heating system depends on the hei...