27
ENGLISH
EN
PARAMETERS
UM
FAMILY
G20
G31
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m³S
45,67x
70,69
Net Calorific Value
MJ/m³S
34,02
88
Supply nominal pressure
mbar (mm H2O)
20 (203,9)
37 (377,3)
Supply minimum pressure
mbar (mm H2O)
10 (102,0)
-
PARAMETERS
25 KIS
30 KIS
35 KIS
G20
G31
G20
G31
G20
G31
Burner: diameter/length
mm
70/86
70/86
70/125
70/125
70/125
70/125
Diaphragm: number and diameter holes
n° - mm
1 - 4,3
1 - 4,3
1 - 5,2
1 - 5,2
1 - 5,2
1 - 5,2
CH maximum gas capacity
Sm³/h
2,12
-
2,64
-
3,38
-
kg/h
-
1,55
-
1,94
-
2,48
DHW maximum gas capacity
Sm³/h
2,64
-
3,17
-
3,66
-
kg/h
-
1,94
-
2,33
-
2,69
CH minimum gas capacity
Sm³/h
0,38
-
0,52
-
0,52
-
kg/h
-
0,39
-
0,54
-
0,54
DHW minimum gas capacity
Sm³/h
0,38
-
0,52
-
0,52
-
kg/h
-
0,39
-
0,54
-
0,54
Number of fan rotations with slow ignition
rpm
5.500
5.500
5.500
5.500
5.500
5.500
Maximum number of CH fan rotations
rpm
6.200
6.000
5.800
5.600
7.300
7.200
Maximum number of DHW fan rotations
rpm
7.600
7.400
6.900
6.700
7.800
7.800
Minimum number of CH/DHW fan rotations
rpm
1.600
2.000
1.700
1.900
1.700
1.900
Max n° of DHW fan rotations in C(10) configuration (Ø60/100 ● Ø80/125 ● Ø80-80)
rpm
7.600
-
-
-
-
-
Max n° of DHW fan rotations in C(10) configuration (Ø60/100)
rpm
-
-
7.250
-
8.200
-
Max n° of DHW fan rotations in C(10) configuration (Ø80/125 ● Ø80-80)
rpm
-
-
6.900
-
7.800
-
Min n° of CH/DHW fan rotations in C(10) configuration (Ø60/100 ● Ø80/125 ● Ø80-80
)
rpm
1.600
-
-
-
-
-
Min n° of CH/DHW fan rotations in C(10) configuration (Ø60/100)
rpm
-
-
1.750
-
1.800
-
Min n° of CH/DHW fan rotations in C(10) configuration (Ø80/125 ● Ø80-80)
rpm
-
-
1.700
-
1.700
-
ADDED DEVICE
Class
Bonus
EXTERNAL PROBE
II
2%
OT CONTROL PANEL* (°)
V
3%
EXTERNAL PROBE + OT CONTROL PANEL*
VI
4%
NOTE (if connected to the boiler the external probe or OT remote control or both devices):
With reference to Delegated Regulation (EU) No. 811/2013, the data in the table can be used for completing the product card and the labelling for ambient heating appliances, for mixed
heating appliances, for assemblies of appliances for ambient heating, and for temperature control devices and solar devices:
(*) Set as room thermostat - (°) Factory supplied configuration
15 ErP DATA
Parameter
Symbol
FAMILY
25 KIS
FAMILY
30 KIS
FAMILY
35 KIS
Unit
Seasonal space heating energy efficiency class
-
A
A
A
-
Water heating energy efficiency class
-
A
A
A
-
Rated heat output
Pnominal
20
24
31
kW
Seasonal space heating energy efficiency
ηs
93
94
94
%
Useful heat output
At rated heat output and high-temperature regime (*)
P4
19,5
24,4
31,2
kW
At 30% of rated heat output and low-temperature regime (**)
P1
6,5
8,2
10,5
kW
Useful efficiency
At rated heat output and high-temperature regime (*)
η4
87,8
88,0
87,9
%
At 30% of rated heat output and low-temperature regime (**)
η1
98,3
98,6
98,6
%
Auxiliary electricity consumption
At full load
elmax
27,0
32,0
49,0
W
At part load
elmin
13,0
13,0
13,0
W
In Stand-by mode
PSB
3,0
3,0
3,0
W
Other parameters
Stand-by heat loss
Pstby
30,2
26,0
26,0
W
Pilot flame energy consumption
Pign
-
-
-
W
Annual energy consumption
QHE
60
75
96
GJ
Sound power level, indoors
LWA
50
50
54
dB
Emissions of nitrogen oxides
NOx
46
35
38
mg/kWh
For combination heaters
Declared load profile
XL
XL
XL
Water heating energy efficiency
ηwh
86
85
85
%
Daily electricity consumption
Qelec
0,155
0,141
0,157
kWh
Daily fuel consumption
Qfuel
22,482
22,942
22,986
kWh
Annual electricity consumption
AEC
34
31
34
kWh
Annual fuel consumption
AFC
17
17
17
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).