background image

FAMILY

12

MENU

DEFAULT VALUE FACTORY 

SET

MINIMUM

 VALUE

MAXIMUM

VALUE

ACCESS LEVEL

NOTES

SET

VALUE     

BOOSTER DELAY

30min

1 min

60 min

INSTALLER

BOOSTER DELTA TEMP

5°C

1°C

20°C

INSTALLER

OAT SENSOR TYP

0

0

3

INSTALLER

MINIMUM PUMP SPEED

19%

19%

100%

INSTALLER

MAXIMUM PUMP SPEED

100%

19%

100%

INSTALLER

ENABLE ERROR HISTORY

SERVICE     

ERROR HISTORY

INSTALLER     

SCREED HEATING

DEACTIVATE FUNCTION

DEACTIVATE FUNCTION

ACTIVATE FUNCTION

INSTALLER: OFF state and 

low temperature system

DEACTIVATE FUNCTION

INSTALLER     

ACTIVATE FUNCTION

INSTALLER     

FUNCTION SETTINGS

SERVICE     

TFMIN

20 °C

15 °C

30 °C

SERVICE     

TFMAX

35 °C

30 °C

55 °C

SERVICE     

COMBUSTION MONITORING

SERVICE     

GAS TYPE

NATURAL GAS

NATURAL GAS / LPG

INSTALLER

BOILER TYPE (*)

A

A / B / C / .....

SERVICE     

COMBUSTION OFFSET

RESTORE

RESTORE

RESET

SERVICE     

ACC AUTO CAL

RESTORE

RESTORE

RESET

SERVICE      

BOILER

INSTALLER     

REMOVE BOILER

INSTALLER      

HYDRAULIC CONFIG

1

0

4

INSTALLER     

0 = only heating / 1 = instantaneous with fl owswitch / 2 = instantaneous with fl owmeter / 

3 = only h water tank with probe / 4 = only h water tank with thermostat

SYSTEM INFO

SERVICE     

(*) BOILER TYPE: see 

“4.23 Combustion Control Parameters”

4  COMMISSIONING

4.1 

Preliminary checks

The first ignition should be carried out by expert personnel from an authorised Technical 

Assistance Service Centre. Before starting up the boiler, check:

 

-

that the data of the supply networks (electricity, water, gas) correspond to the label data

 

-

that the extraction pipes of the flue gases and the air suction pipes are working correctly

 

-

that conditions for regular maintenance are guaranteed if the boiler is placed inside or 

between items of furniture

 

-

the seal of the fuel adduction system

 

-

that the fuel flow rate corresponds to values required by the boiler

 

-

that the fuel supply system is sized to provide the correct flow rate to the boiler, and that 

it has all the safety and control devices required by current regulations

 

-

that the circulator rotates freely because, especially after long periods of inactivity, 

deposits and/or debris can prevent free rotation (see 15.4 “Eventual releasing of the 

circulator shaft”).

4.2 

Programming the boiler

 

-

Position the system’s master switch to the “on” position. The boiler display looks like this: 

FRI

09/04/2021

12:17

MENU

INFO

SET

PLANT

HOT WATER TEMPERATURE

STATE

42

°C

1.3 bar

 

-

In some cases it may be necessary to set the TIME and DATE; in this case the machine 

interface request you to carry out the operation with the message “SET TIME AND 

DATE”. Navigate with the keys to set the values.

ENTER TIME AND DATE

USE THE ARROWS TO MODIFY

12

17

09/04/2021

:

TIME & DATE

Note:

 it is possible to change the TIME and DATE, DAYLIGHT SAVINGS TIME settings, as 

well as the LANGUAGE and the duration of the back-lighting, even afterwards by entering 

the MENU from the main screen and then selecting SETTINGS.

Note:

 The device automatically manages the change of time from solar to daylight savings 

time and vice versa.

 

b

Each time that the boiler is powered an automatic venting cycle is carried out lasting 

4 min. To interrupt the vent cycle, carry out the procedure explained in “4.3 First 

commissioning”.

 

-

Set the boiler to OFF   selecting, from REC10CH, STATE 

 BOILER.

42

°C

MENU

STATE

SET

INFO

HOT WATER TEMPERATURE

FRI

1.3 

bar

09/04/2021

12:17  

PLANT

BOILER

MAIN ZONE

STATE

OFF

HOT WATER ONLY

HEATING AND HOT WATER

BOILER

 

-

Through the REC10CH it is possible to access, using the TECHNICAL menu, a series 

of parameters that can be programmed to allow you to personalise the operation of the 

boiler based on the type of system. There are 3 access levels: USER, INSTALLER and 

SERVICE (see “3.1 Structure of the MENU tree of the REC10CH”).

 

-

Access the parameters and set the operation according to your type of system.

4.2.1 

Boiler configuration

 

-

Select PARAMETERS.

PARAMETERS

WEATHER COMPENSATION

INSTALLATION

RANGE RATED

CALIBRATION

INSTALLER

TECHNICAL

Содержание 20187642

Страница 1: ...Family KIS EN INSTALLER AND USER MANUAL...

Страница 2: ...ser also Warning This instructions manual contains data and information for both the user and the installer Specifically note that the user for the use of the appliance must refer to chapters Warnings...

Страница 3: ...this case ventilate the room by opening the doors and windows close the fuel shut off device ask the Technical Assistance Service or professionally qualified personnel to intervene promptly a It is f...

Страница 4: ...pe and consider any increase in the diameter of the pipe itself The condensation exhaust pipe must always have an adequate slope level to prevent the condensation from stagnating and its proper draina...

Страница 5: ...and immediately before and after each change of direction curve b The boiler is supplied without the flue gas exhaust air suction kit since it is possible to use the accessories for condensing applia...

Страница 6: ...e can exceed the static pressure of the collective air duct of 25 Pa in the condition in which n 1 boilers work at maximum rated heat input and 1 boiler at the minimum rated heat input allowed by the...

Страница 7: ...e vent cycle Remove any air in the domestic system radiators zone manifolds etc using the bleed valves Once again check that the system pressure is correct ideally 1 1 5 bar and restore the levels if...

Страница 8: ...is in progress number 1 is flashing This icon indicates that the circuit for domestic hot water production is enabled When a domestic hot water request is in progress the icon flashes The P at the to...

Страница 9: ...LER CHANGE NAME INSTALLER PI PROPORTIONAL 5 0 99 SERVICE only mixing zones with ACTUATION BE16 PI INTEGRAL 10 0 99 SERVICE only mixing zones with ACTUATION BE16 VALVE RUN 120 sec 0 sec 120 sec SERVICE...

Страница 10: ...request type TA and zone type HT 0 4 0 2 0 8 INSTALLER if EXTERNAL PROBE request type TA and zone type LT 2 0 1 0 5 0 INSTALLER if request type AMBIENT PROBE or REC10CH AMBIENT INFLUENCE 10 0 20 INSTA...

Страница 11: ...DISABLE COOLING FUNCTION NOT ACTIVE FUNCTION ACTIVE FUNCTION NOT ACTIVE INSTALLER USE FOR DHW DON TUSE FOR DHW DHW FUNCTION NOT ACTIVE DHW FUNCTION ACTIVE DHW FUNCTION NOT ACTIVE INSTALLER if BE17 pre...

Страница 12: ...t it has all the safety and control devices required by current regulations that the circulator rotates freely because especially after long periods of inactivity deposits and or debris can prevent fr...

Страница 13: ...ZONE PARAMETERS WEATHER COMPENSATION INSTALLATION RANGE RATED CALIBRATION INSTALLER TECHNICAL SENSOR CALIBRATION ZONES MANAGER SYSTEM RESET INSTALLER INSTALLATION ADD ZONE MODIFY ZONE DELETE ZONE INS...

Страница 14: ...URE C EXTERNAL TEMPERATURE C NIGHT COMPENSATION If a timer is connected to the ROOM THERMOSTAT input the NIGHT COMP function can be enabled as follows menu TECHNICAL WEATHER COMPENSATION CLIMATIC CURV...

Страница 15: ...in standby again keeping the outlet temperature displayed If faults arise in ignition or operations the boiler performs a SAFETY STOP the triangle signalling faults will flash on the REC10CH To identi...

Страница 16: ...Technical Assistance Centre 4 13 Gas conversion Conversion from a family gas to other family gas can be performed easily also when the boiler is installed This operation must be carried out by profes...

Страница 17: ...l E042 water pressure transducer fault definitive E060 domestic hot water probe fault transitional E070 flow sensor faulty flow sensor overtemperature flow return sensor differential alarm transitiona...

Страница 18: ...TECHNICAL Note After a reset it is necessary to carry out a new configuration of the system for details about this procedure see the following section 4 19 System configuration b This operation must b...

Страница 19: ...in intact and to comply with prescriptions of current regulations it is necessary to render the appliance to systematic checks at regular intervals When carrying out maintenance work observe the instr...

Страница 20: ...nnect the tubes A and B remove the clip C and remove the siphon Unscrew the bottom and top caps then remove the float Clean the parts of the siphon from any solid residues b Do not remove the safety s...

Страница 21: ...EFAULT VALUE FACTORY SET MINIMUM VALUE MAXIMUM VALUE ACCESS LEVEL NOTES MENU SETTINGS USER TIME DATE USER DAYLIGHT SAVINGS TIME FUNCTION ACTIVE FUNCTION NOT ACTIVE FUNCTION ACTIVE USER LANGUAGE ITALIA...

Страница 22: ...ed programme 8 2 3 MANUAL If MANUAL is selected the zone requests will be managed based on the setpoint set by the user 8 2 4 HEAT OFF If HEAT OFF is selected the zone requests will not be fulfilled N...

Страница 23: ...0 INFO The INFO function can be used to display a series of data regarding the system ATTENTION The displayed data cannot be modified SCREED HEATER OPERATING HOURS DELIVERY PROBE RETURN PROBE DOMESTIC...

Страница 24: ...TART THURSDAY USE THE ARROWS TO MODIFY ENTER START TIME ADD PERIOD END MAIN Once the operation completed the display will show 07 30 08 30 11 30 14 00 13 30 15 00 18 00 22 30 START THURSDAY ADD MODIFY...

Страница 25: ...TURE WILL BE ADJUSTED WITH NEW TARGET SET POINT UNTIL 09 04 2021 ON 13 15 1 ZONE1 CONFIRM CANCEL 00 30 YOU ARE ACTIVATING COMFORT MODE ENTER TIME DURATION IN HOURS USE THE ARROWS TO MODIFY 1 ZONE1 26...

Страница 26: ...Maximum pressure bar 8 8 8 Minimum pressure bar 0 15 0 15 0 15 Quantity of hot water with t 25 C 30 C 35 C l min 15 1 12 5 10 8 18 1 15 1 12 9 20 8 17 4 14 9 DHW minimum capacity l min 2 2 2 Selectio...

Страница 27: ...ith reference to Delegated Regulation EU No 811 2013 the data in the table can be used for completing the product card and the labelling for ambient heating appliances for mixed heating appliances for...

Страница 28: ...ivery 34 Hot water 35 Gas 36 Heating return 37 Cold water 2 21 AF AC M R 20 19 1 6 6 8 9 5 4 6 7 3 2 18 15 14 13 12 11 10 16 17 15 3 Residual head of circulator Fig 3 A B C Residual head mbar Flow rat...

Страница 29: ...entering a value 10 the circulator speed will change to achieve a system flow rate with the aim of maintain ing the T of 10 C upstream and down stream of the exchanger 3 CIRCULATOR IN MAXIMUM FIXED S...

Страница 30: ...Wiring diagram Blu Blue Marrone Brown Nero Black Rosso Red Bianco White Viola Violet Rosa Pink Arancione Orange Grigio Grey Giallo Yellow Verde Green A Gas valve B 230V auxiliary C Voltage free contac...

Страница 31: ...from 60 100 to 80 80 110 65 65 1 1 5 90 bend 60 100 60 100 horizontal 10 horizontal 6 horizontal 6 1 3 1 6 105 vertical 11 vertical 7 vertical 7 90 bend 80 125 80 125 25 15 15 1 1 5 130 adaptor from 6...

Страница 32: ...T OPTION 4 and SYSTEM INFO INSTALLATION WEATHER COMPENSATION RANGE RATED TECHNICAL INSTALLER 5 PARAMETERS CALIBRATION and ANTI CYCLE FUNCTION RESET CH TIMERS DHW THERMOSTAT PARAMETERS INSTALLER 6 PUMP...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...Cod 20187595 09 21 Ed 3...

Отзывы: