FAMILY
12
MENU
DEFAULT VALUE FACTORY
SET
MINIMUM
VALUE
MAXIMUM
VALUE
ACCESS LEVEL
NOTES
SET
VALUE
BOOSTER DELAY
30min
1 min
60 min
INSTALLER
BOOSTER DELTA TEMP
5°C
1°C
20°C
INSTALLER
OAT SENSOR TYP
0
0
3
INSTALLER
MINIMUM PUMP SPEED
19%
19%
100%
INSTALLER
MAXIMUM PUMP SPEED
100%
19%
100%
INSTALLER
ENABLE ERROR HISTORY
SERVICE
ERROR HISTORY
INSTALLER
SCREED HEATING
DEACTIVATE FUNCTION
DEACTIVATE FUNCTION
ACTIVATE FUNCTION
INSTALLER: OFF state and
low temperature system
DEACTIVATE FUNCTION
INSTALLER
ACTIVATE FUNCTION
INSTALLER
FUNCTION SETTINGS
SERVICE
TFMIN
20 °C
15 °C
30 °C
SERVICE
TFMAX
35 °C
30 °C
55 °C
SERVICE
COMBUSTION MONITORING
SERVICE
GAS TYPE
NATURAL GAS
NATURAL GAS / LPG
INSTALLER
BOILER TYPE (*)
A
A / B / C / .....
SERVICE
COMBUSTION OFFSET
RESTORE
RESTORE
RESET
SERVICE
ACC AUTO CAL
RESTORE
RESTORE
RESET
SERVICE
BOILER
INSTALLER
REMOVE BOILER
INSTALLER
HYDRAULIC CONFIG
1
0
4
INSTALLER
0 = only heating / 1 = instantaneous with fl owswitch / 2 = instantaneous with fl owmeter /
3 = only h water tank with probe / 4 = only h water tank with thermostat
SYSTEM INFO
SERVICE
(*) BOILER TYPE: see
“4.23 Combustion Control Parameters”
4 COMMISSIONING
4.1
Preliminary checks
The first ignition should be carried out by expert personnel from an authorised Technical
Assistance Service Centre. Before starting up the boiler, check:
-
that the data of the supply networks (electricity, water, gas) correspond to the label data
-
that the extraction pipes of the flue gases and the air suction pipes are working correctly
-
that conditions for regular maintenance are guaranteed if the boiler is placed inside or
between items of furniture
-
the seal of the fuel adduction system
-
that the fuel flow rate corresponds to values required by the boiler
-
that the fuel supply system is sized to provide the correct flow rate to the boiler, and that
it has all the safety and control devices required by current regulations
-
that the circulator rotates freely because, especially after long periods of inactivity,
deposits and/or debris can prevent free rotation (see 15.4 “Eventual releasing of the
circulator shaft”).
4.2
Programming the boiler
-
Position the system’s master switch to the “on” position. The boiler display looks like this:
FRI
09/04/2021
12:17
MENU
INFO
SET
PLANT
HOT WATER TEMPERATURE
STATE
42
°C
1.3 bar
-
In some cases it may be necessary to set the TIME and DATE; in this case the machine
interface request you to carry out the operation with the message “SET TIME AND
DATE”. Navigate with the keys to set the values.
ENTER TIME AND DATE
USE THE ARROWS TO MODIFY
12
17
09/04/2021
:
TIME & DATE
Note:
it is possible to change the TIME and DATE, DAYLIGHT SAVINGS TIME settings, as
well as the LANGUAGE and the duration of the back-lighting, even afterwards by entering
the MENU from the main screen and then selecting SETTINGS.
Note:
The device automatically manages the change of time from solar to daylight savings
time and vice versa.
b
Each time that the boiler is powered an automatic venting cycle is carried out lasting
4 min. To interrupt the vent cycle, carry out the procedure explained in “4.3 First
commissioning”.
-
Set the boiler to OFF selecting, from REC10CH, STATE
BOILER.
42
°C
MENU
STATE
SET
INFO
HOT WATER TEMPERATURE
FRI
1.3
bar
09/04/2021
12:17
PLANT
BOILER
MAIN ZONE
STATE
OFF
HOT WATER ONLY
HEATING AND HOT WATER
BOILER
-
Through the REC10CH it is possible to access, using the TECHNICAL menu, a series
of parameters that can be programmed to allow you to personalise the operation of the
boiler based on the type of system. There are 3 access levels: USER, INSTALLER and
SERVICE (see “3.1 Structure of the MENU tree of the REC10CH”).
-
Access the parameters and set the operation according to your type of system.
4.2.1
Boiler configuration
-
Select PARAMETERS.
PARAMETERS
WEATHER COMPENSATION
INSTALLATION
RANGE RATED
CALIBRATION
INSTALLER
TECHNICAL