4.Service Tables
71
output
0: Off
1: On (Forbid
output)
7
Not used
Do not change this setting.
G3 Switch 02 (SP No. 1-105-003)
No Function
Comments
0
G3 protocol mode
used
0: Standard and non-
standard
1: Standard only
Change this bit to 1 only when the other end can only communicate with machines
that send T.30-standard frames only.
1: Disables NSF/NSS signals (these are used in non-standard mode
communication)
1-
6
Not used
Do not change the settings.
7
Short preamble
0: Disabled 1: Enabled
Refer to Appendix B in the Group 3 Facsimile Manual for details about Short
Preamble.
G3 Switch 03 (SP No. 1-105-004)
No Function
Comments
0
DIS detection number
(Echo countermeasure)
0: 1
1: 2
0: The machine will hang up if it receives the same DIS frame twice.
1: Before sending DCS, the machine will wait for the second DIS which is
caused by echo on the line.
1
Not Used
Do not change the settings.
2
Not Used
Do not change the settings.
3
ECM frame size
0: 256 bytes
1: 64 bytes
Keep this bit at "0" in most cases.
4
CTC transmission conditions
0: After one PPR signal received
1: After four PPR signals
received (ITU-T standard)
0: When using ECM in non-standard (NSF/NSS) mode, the machine sends
a CTC to drop back the modem rate after receiving a PPR, if the following
condition is met in communications at 14.4, 12.0, 9.6, and 7.2 kbps.
NTransmit- Number of transmitted frames
NResend- Number of frames to be retransmitted
1: When using ECM, the machine sends a CTC to drop back the modem
rate after receiving four PPRs.
Содержание M0A0
Страница 2: ......
Страница 10: ...8 ...
Страница 12: ......
Страница 30: ...2 Installation 18 Destination For printing images For operating NA 8 66 10 8 66 15 EU AP CHN 10 15 ...
Страница 33: ...2 Installation 21 6 Enter the password again 7 Press OK 8 Change the Administrator 1 login password ...
Страница 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Страница 85: ...2 Installation 73 ...
Страница 127: ...4 Replacement and Adjustment 115 PCDU PCDU 1 Open the front cover A 2 Hold the grip to pull the PCDU A out ...
Страница 189: ...4 Replacement and Adjustment 177 ...
Страница 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Страница 229: ...5 System Maintenance 217 LDAP authorization information ...
Страница 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Страница 358: ...7 Detailed Descriptions 346 ...
Страница 367: ...Latest Release Initial Release August 2016 Copyright c 2016 Ricoh Co Ltd MP 402SPF Machine Code M0A0 Appendices ...
Страница 368: ......
Страница 558: ......
Страница 560: ...2 Software Update Errors 57 Errors That Occur When the Control Panel Downloads Data from the Controller at Startup 62 ...
Страница 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Страница 622: ......
Страница 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Страница 626: ......
Страница 632: ...1 Installation 6 ...
Страница 703: ...4 Service Tables 77 0 Off 1 On change occurs such as an optical fiber line 5 7 Not used Do not change the settings ...
Страница 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Страница 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Страница 760: ......
Страница 762: ......
Страница 766: ...1 Detailed Descriptions 4 SW 1 SW 2 SW 3 Paper Size 7 H L H Half Letter SEF 8 H H H Paper cassette is not set ...
Страница 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...