6.Troubleshooting
277
SC No. Level
Error Name/Error Condition/Major Cause/Solution
to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD,
HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data
and check them.
SC No. Level
Error Name/Error Condition/Major Cause/Solution
SC863-
13
D
HDD data read failure
The data written to the HDD cannot be read normally.
Bad sectors were generated during operation.
(An error occurred in partition "l".)
Guide for when to replace the HDD
1.
When SC863 has occurred ten times or more
The interval is short.
Repeatedly occurs in the same situation (At power-on, etc.).
Startup takes a long time when the main power is turned on.
2.
It takes a long time after main power on for the operation panel to become ready.
HDD access may be consuming time. Normal HDD access time after main power on is
about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20
to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD,
HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data
and check them.
SC No. Level
Error Name/Error Condition/Major Cause/Solution
SC863-
14
D
HDD data read failure
The data written to the HDD cannot be read normally.
Bad sectors were generated during operation.
(An error occurred in partition "m".)
Guide for when to replace the HDD
1.
When SC863 has occurred ten times or more
The interval is short.
Repeatedly occurs in the same situation (At power-on, etc.).
Startup takes a long time when the main power is turned on.
2.
It takes a long time after main power on for the operation panel to become ready.
HDD access may be consuming time. Normal HDD access time after main power on is
about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20
to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD,
HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data
and check them.
Содержание M0A0
Страница 2: ......
Страница 10: ...8 ...
Страница 12: ......
Страница 30: ...2 Installation 18 Destination For printing images For operating NA 8 66 10 8 66 15 EU AP CHN 10 15 ...
Страница 33: ...2 Installation 21 6 Enter the password again 7 Press OK 8 Change the Administrator 1 login password ...
Страница 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Страница 85: ...2 Installation 73 ...
Страница 127: ...4 Replacement and Adjustment 115 PCDU PCDU 1 Open the front cover A 2 Hold the grip to pull the PCDU A out ...
Страница 189: ...4 Replacement and Adjustment 177 ...
Страница 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Страница 229: ...5 System Maintenance 217 LDAP authorization information ...
Страница 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Страница 358: ...7 Detailed Descriptions 346 ...
Страница 367: ...Latest Release Initial Release August 2016 Copyright c 2016 Ricoh Co Ltd MP 402SPF Machine Code M0A0 Appendices ...
Страница 368: ......
Страница 558: ......
Страница 560: ...2 Software Update Errors 57 Errors That Occur When the Control Panel Downloads Data from the Controller at Startup 62 ...
Страница 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Страница 622: ......
Страница 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Страница 626: ......
Страница 632: ...1 Installation 6 ...
Страница 703: ...4 Service Tables 77 0 Off 1 On change occurs such as an optical fiber line 5 7 Not used Do not change the settings ...
Страница 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Страница 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Страница 760: ......
Страница 762: ......
Страница 766: ...1 Detailed Descriptions 4 SW 1 SW 2 SW 3 Paper Size 7 H L H Half Letter SEF 8 H H H Paper cassette is not set ...
Страница 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...