RD 500 RD51
Converter Technical Data
3-9
DOK-RD500*RD51*******-IB04-EN-P
4 kHz
8 kHz
RD51.1
132
160
200
315
400
132
160
200
315
400
Peak power for t = 0.1 s kW
270
270
370
2x270 2x370 270
270
370
2x270 2x370
Minimum resistance value
Ω
2.2
2.2
1.6
2x2.2
2x1.6
2.2
2.2
1.6
2x2.2
2x1.6
1:
Max. permissible motor power based on 4-pin standard induction
motor
2:
Starting at an output voltage Ua >400 V, the rated current is linearly
reduced from 100 % to 83 % for Va = 480 V.
3:
Additional function W1 required
4:
If Output frequency >150 Hz the additional function M1 is required
(without integrate Motor filter)
3.9
Technical Data for Size Classes G and H with Pulse
Frequency f
p
= 12 kHz
12 kHz
RD51
132
160
200
315
400
Supply voltage, 3-phase 380 ... 480 V AC (±10 %)
1)
Output frequency
3)
Hz
0 - 1000
0 - 500
Rated current
A 140
170
210
310
395
Peak current for t = 60 s A 182
221
273
403
514
t = 1 s A 238
289
357
527
672
Rated output S
N
kVA 92
112
138
204
260
Peak power for t = 60 s kVA 120
145
180
265
338
Ambient conditions, noise suppression level, interference immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0 – 40 °C
operation, to 50 °C power reduction at 2.5 % per K)
Cooling air requirement
m³ / s
0.4
0.4
0.6
0.8
1.2
Power loss
3.0
3.
4.6
6.8
8.6
Radio int. sup. level/noise immunity
A 1 according to EN 55011 / EN 61800-3
Mechanical design
Size classes
G
G
G
H
H
Degree of protection
IP 20 according to EN 60529 (without connection terminals)
Weight of converter for the various cooling types
F Forced air cooling with integrated
liquid circuit kg 180
180
180
358
358
R Liquid cooling with
internal pump kg
157
157
157
312
312
Performance data of chopper
Continuous power kW
40
40
40
2 x 40
2 x 40
Continuous power
2)
kW 100
100
100
2 x 100
2 x 100
Peak power for t = 0.1 s kW
270
270
370
2 x 270
2 x 370
Minimum resistance value
Ω
2.2
2.2
1.6
2 x 2.2
2 x 1.6
1):
Starting at an output voltage Ua >400 V, the rated current is linearly
reduced from 100 % to 83 % for Ua = 480 V.
2):
Additional function W1 required
3):
If Output frequency >150 Hz the additional function M1 is required
(without integrate Motor filter)
Содержание RD 500 Series
Страница 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Страница 275: ......